Datasheet Texas Instruments OPA369

ManufacturerTexas Instruments
SeriesOPA369
Datasheet Texas Instruments OPA369

1.8V, 700nA, Zero-Crossover Rail-To-Rail I/O Operational Amplifier

Datasheets

1.8V, 700nA, ZerГё-Crossover RAIL-TO-RAIL I/O OPERATIONAL AMPLIFIER datasheet
PDF, 1.3 Mb, Revision: B, File published: Dec 5, 2008
Extract from the document

Prices

Status

OPA369AIDCKROPA369AIDCKT
Lifecycle StatusActive (Recommended for new designs)Active (Recommended for new designs)
Manufacture's Sample AvailabilityYesNo

Packaging

OPA369AIDCKROPA369AIDCKT
N12
Pin55
Package TypeDCKDCK
Industry STD TermSOT-SC70SOT-SC70
JEDEC CodeR-PDSO-GR-PDSO-G
Package QTY3000250
CarrierLARGE T&RSMALL T&R
Device MarkingCJSCJS
Width (mm)1.251.25
Length (mm)22
Thickness (mm).9.9
Pitch (mm).65.65
Max Height (mm)1.11.1
Mechanical DataDownloadDownload

Parametrics

Parameters / ModelsOPA369AIDCKR
OPA369AIDCKR
OPA369AIDCKT
OPA369AIDCKT
Additional FeaturesEMI Hardened,Zero CrossoverEMI Hardened,Zero Crossover
ArchitectureCMOSCMOS
CMRR(Min), dB100100
CMRR(Typ), dB114114
GBW(Typ), MHz0.0120.012
Input Bias Current(Max), pA5050
Iq per channel(Max), mA0.00120.0012
Iq per channel(Typ), mA0.00080.0008
Number of Channels11
Offset Drift(Typ), uV/C0.40.4
Operating Temperature Range, C-40 to 85-40 to 85
Output Current(Typ), mA1010
Package GroupSC70SC70
Package Size: mm2:W x L, PKG5SC70: 4 mm2: 2.1 x 2(SC70)5SC70: 4 mm2: 2.1 x 2(SC70)
Rail-to-RailIn,OutIn,Out
RatingCatalogCatalog
Slew Rate(Typ), V/us0.0050.005
Total Supply Voltage(Max), +5V=5, +/-5V=105.55.5
Total Supply Voltage(Min), +5V=5, +/-5V=101.81.8
Vn at 1kHz(Typ), nV/rtHz290290
Vos (Offset Voltage @ 25C)(Max), mV0.750.75

Eco Plan

OPA369AIDCKROPA369AIDCKT
RoHSCompliantCompliant

Application Notes

  • Zero-crossover Amplifiers: Features and Benefits (Rev. A)
    PDF, 296 Kb, Revision: A, File published: Feb 9, 2017
  • Tuning in Amplifiers
    PDF, 44 Kb, File published: Oct 2, 2000
    Have you ever had the experience of designing an analog gain block with an amplifier that is specified to be unity gain stable only to find that it is oscillating out of control in your circuit? Or have you ever replaced a stable voltage feedback amplifier with a current feedback amplifier to find that the current feedback amplifier immediately oscillates when placed in the amplifier socket? Oscil
  • Single-Supply Operation of Operational Amplifiers
    PDF, 77 Kb, File published: Oct 2, 2000
    Operation of op amps from single supply voltages is useful when negative supply voltages are not available. Furthermore, certain applications using high voltage and high current op amps can derive important benefits from single supply operation.
  • Op Amp Performance Analysis
    PDF, 76 Kb, File published: Oct 2, 2000
    This bulletin reflects the analysis power gained through knowledge of an op amp circuit's feedback factor. Feedback dictates the performance of an op amp both in function and in quality. The major specifications of the amplifier descibe an open-loop device awaiting feedback direction of the end circuit's function. Just how well the amplifier performs the function reflects through the feedback inte

Model Line

Series: OPA369 (2)

Manufacturer's Classification

  • Semiconductors> Amplifiers> Operational Amplifiers (Op Amps)> Ultra-Low-Power Op Amps (<=250uA)
EMS supplier