Datasheet Linear Technology LT1002

ManufacturerLinear Technology
SeriesLT1002

Dual, Matched Precision Operational Amplifier

Datasheets

Datasheet LT1002
PDF, 188 Kb, Language: en, File uploaded: Apr 21, 2017, Pages: 16
Dual, Matched Precision Operational Amplifier
Extract from the document

Prices

Packaging

LT1002ACN#PBFLT1002CN#PBF
N12
PackageN-14
Package Outline Drawing
N-14
Package Outline Drawing
Package CodeNN
Package Index05-08-1510 (N14)05-08-1510 (N14)
Pin Count1414

Parametrics

Parameters / ModelsLT1002ACN#PBFLT1002CN#PBF
Av Min Stable, V/V11
Avol, dB5858
Common Mode Rejection Ratio, dB126126
Number of Channels22
Cload, pF2000020000
Design ToolsLTspice FileLTspice File
Enoise 1/f Corner, Hz44
Enoise Density, nV/rtHz9.69.6
Export Controlnono
GBW, MHz0.80.8
Ibias, nA0.60.6
Inoise, pA/rtHz0.10.1
Inoise 1/f Corner, Hz7070
Ios, µA0.00030.0003
Iout, mA2525
Isupply, mA1.531.53
LF Enoise, µVPP0.350.35
Operating Temperature Range, °C0 to 700 to 70
Over-the-Topnono
PSRR, dB123123
Rail-to-Rail Innono
Rail-to-Rail Outnono
SR, V/µs0.250.25
Shutdownnono
Single Supplynono
TypeVFBVFB
VinCM High (from V+), V0.90.9
VinCM Low (from V-), V0.90.9
Voh (from V+), V11
Vol (from V-), V11
Vos, mV0.020.02
Vos TC, µV/C0.20.2
Vs Max, V4444
Vs Min, V66

Eco Plan

LT1002ACN#PBFLT1002CN#PBF
RoHSCompliantCompliant

Application Notes

  • High Speed Comparator Techniques &mdash AN13
    PDF, 1.1 Mb, File published: Apr 1, 1985
    The AN13 is an extensive discussion of the causes and cures of problems in very high speed comparator circuits. A separate applications section presents circuits, including a 0.025% accurate 1Hz to 30MHz V/F converter, a 200ns 0.01% sample-hold and a 10MHz fiber-optic receiver. Five appendices covering related topics complete this note.
    Extract from the document
  • Thermal Techniques in Measurement and Control Circuitry &mdash AN5
    PDF, 175 Kb, File published: Dec 1, 1984
    6 applications utilizing thermally based circuits are detailed. Included are a 50MHz RMS to DC converter, and anemometer, a liquid flow meter and others. A general discussion of thermodynamic considerations involved in circuitry is also presented.
    Extract from the document
  • Applications of New Precision Op Amps &mdash AN6
    PDF, 784 Kb, File published: Jan 1, 1985
    Application considerations and circuits for the LT1001 and LT1002 single and dual precision amplifiers are illustrated in a number of circuits, including strain gauge signal conditioners, linearized platinum RTD circuits, an ultra precision dead zone circuit for motor servos and other examples.

Design Notes

  • Updated Operational Amplifier Selection Guide for Optimum Noise Performance &mdash DN140
    PDF, 74 Kb, File published: Oct 1, 1996
    Extract from the document
  • 3V Operation of Linear Technology Op Amps &mdash DN56
    PDF, 78 Kb, File published: Feb 1, 1992
    Extract from the document

Model Line

Series: LT1002 (2)

Manufacturer's Classification

  • Signal Conditioning > Amplifiers > Operational Amplifiers (Op Amps) > Precision Amplifiers (Vos | Low Noise Amplifiers ( | High Voltage Amplifiers (>12V)
EMS supplier