Datasheet Texas Instruments OPA132UG4

ManufacturerTexas Instruments
SeriesOPA132
Part NumberOPA132UG4
Datasheet Texas Instruments OPA132UG4

High Speed FET-Input Operational Amplifiers 8-SOIC

Datasheets

OPAx132 High-Speed FET-Input Operational Amplifiers datasheet
PDF, 1.1 Mb, Revision: B, File published: Sep 29, 2015
Extract from the document

Prices

Status

Lifecycle StatusActive (Recommended for new designs)
Manufacture's Sample AvailabilityYes

Packaging

Pin88
Package TypeDD
Industry STD TermSOICSOIC
JEDEC CodeR-PDSO-GR-PDSO-G
Package QTY7575
CarrierTUBETUBE
Device MarkingOPA132U
Width (mm)3.913.91
Length (mm)4.94.9
Thickness (mm)1.581.58
Pitch (mm)1.271.27
Max Height (mm)1.751.75
Mechanical DataDownloadDownload

Parametrics

Additional FeaturesN/A
ArchitectureFET
CMRR(Min)86 dB
CMRR(Typ)94 dB
GBW(Typ)8 MHz
Input Bias Current(Max)50 pA
Iq per channel(Max)4.8 mA
Iq per channel(Typ)4 mA
Number of Channels1
Offset Drift(Typ)2 uV/C
Operating Temperature Range-40 to 125 C
Output Current(Typ)40 mA
Package GroupSOIC
Package Size: mm2:W x L8SOIC: 29 mm2: 6 x 4.9(SOIC) PKG
Rail-to-RailIn,Out
RatingCatalog
Slew Rate(Typ)20 V/us
Total Supply Voltage(Max)36 +5V=5, +/-5V=10
Total Supply Voltage(Min)5 +5V=5, +/-5V=10
Vn at 1kHz(Typ)8 nV/rtHz
Vos (Offset Voltage @ 25C)(Max)0.5 mV

Eco Plan

RoHSCompliant

Application Notes

  • Compensate Transimpedance Amplifiers Intuitively (Rev. A)
    PDF, 69 Kb, Revision: A, File published: Mar 30, 2005
    Transimpedance amplifiers are used to convert low-level photodiode currents to usable voltage signals. All too often, the amplifiers have to be empirically compensated to operate properly. The problem can be easily understood if one looks at all the elements involved.
  • Tuning in Amplifiers
    PDF, 44 Kb, File published: Oct 2, 2000
    Have you ever had the experience of designing an analog gain block with an amplifier that is specified to be unity gain stable only to find that it is oscillating out of control in your circuit? Or have you ever replaced a stable voltage feedback amplifier with a current feedback amplifier to find that the current feedback amplifier immediately oscillates when placed in the amplifier socket? Oscil
  • Single-Supply Operation of Operational Amplifiers
    PDF, 77 Kb, File published: Oct 2, 2000
    Operation of op amps from single supply voltages is useful when negative supply voltages are not available. Furthermore, certain applications using high voltage and high current op amps can derive important benefits from single supply operation.
  • Op Amp Performance Analysis
    PDF, 76 Kb, File published: Oct 2, 2000
    This bulletin reflects the analysis power gained through knowledge of an op amp circuit's feedback factor. Feedback dictates the performance of an op amp both in function and in quality. The major specifications of the amplifier descibe an open-loop device awaiting feedback direction of the end circuit's function. Just how well the amplifier performs the function reflects through the feedback inte

Model Line

Manufacturer's Classification

  • Semiconductors > Amplifiers > Operational Amplifiers (Op Amps) > Precision Op Amps
EMS supplier