Datasheet Texas Instruments LPV801DBVT

ManufacturerTexas Instruments
SeriesLPV801
Part NumberLPV801DBVT
Datasheet Texas Instruments LPV801DBVT

Single Channel 450nA Nanopower Operational Amplifier 5-SOT-23 -40 to 125

Datasheets

LPV801/LPV802 320 nA Nanopower Operational Amplifiers datasheet
PDF, 1.3 Mb, Revision: B, File published: Nov 16, 2016
Extract from the document

Prices

Status

Lifecycle StatusActive (Recommended for new designs)
Manufacture's Sample AvailabilityNo

Packaging

Pin5
Package TypeDBV
Industry STD TermSOT-23
JEDEC CodeR-PDSO-G
Package QTY250
CarrierSMALL T&R
Device Marking15VM
Width (mm)1.6
Length (mm)2.9
Thickness (mm)1.2
Pitch (mm).95
Max Height (mm)1.45
Mechanical DataDownload

Parametrics

Additional FeaturesEMI Hardened
ArchitectureCMOS
CMRR(Min)80 dB
CMRR(Typ)98 dB
GBW(Typ)0.008 MHz
Iq per channel(Max)0.00054 mA
Iq per channel(Typ)0.00045 mA
Number of Channels1
Offset Drift(Typ)1.5 uV/C
Operating Temperature Range-40 to 125 C
Output Current(Typ)4.7 mA
Package GroupSOT-23
Package Size: mm2:W x L5SOT-23: 8 mm2: 2.8 x 2.9(SOT-23) PKG
Rail-to-RailIn to V-,Out
RatingCatalog
Slew Rate(Typ)0.0018 V/us
Total Supply Voltage(Max)5.5 +5V=5, +/-5V=10
Total Supply Voltage(Min)1.6 +5V=5, +/-5V=10
Vn at 1kHz(Typ)420 nV/rtHz
Vos (Offset Voltage @ 25C)(Max)3.5 mV

Eco Plan

RoHSCompliant

Design Kits & Evaluation Modules

  • Evaluation Modules & Boards: DIP-ADAPTER-EVM
    DIP Adapter Evaluation Module
    Lifecycle Status: Active (Recommended for new designs)

Application Notes

  • LPV801 Micropower Ionization Smoke Detector
    PDF, 127 Kb, File published: Nov 29, 2016
    Ionizationdetectors,as usedin smokealarms,outputa very low currentthat requiresa bufferamplifiertointerfaceto the alarmcircuitry.Thisrequiresa bufferamplifierwith low inputbiascurrent,and,sinceasmokedetectoris a always-on device,the amplifiermustalsohavea verylow quiescentcurrenttomaximizethe batterylife. Thisapplicati
  • Comparing EMI Performance of LPV802 with Other Devices in a Gas Sensor App
    PDF, 4.0 Mb, File published: Oct 18, 2016
    Passing the IEC61000-4-3 Radiated EMI test is a requirement for preparing a product for many industrial,medical and consumer markets. This application note presents the results of a simple comparison of theLPV802 nanopower operational amplifier and two other competing devices in a Carbon Monoxide gassensor circuit while subjected to IEC61000-4-3 EMC test conditions.
  • Extend Battery Life and Simplify Calibration in Gas Sensing Applications
    PDF, 140 Kb, File published: Sep 22, 2017
  • Precision Voltage Offset: When Does it Matter? (Rev. A)
    PDF, 271 Kb, Revision: A, File published: Nov 2, 2016

Model Line

Series: LPV801 (3)

Manufacturer's Classification

  • Semiconductors > Amplifiers > Operational Amplifiers (Op Amps) > Ultra-Low-Power Op Amps (<=10uA)