Datasheet Texas Instruments ADS1296R

ManufacturerTexas Instruments
SeriesADS1296R
Datasheet Texas Instruments ADS1296R

6-Channel, 24-Bit Analog-To-Digital Converter w/Integrated Respiration Impedance and ECG Front End

Datasheets

ADS129x Low-Power, 8-Channel, 24-Bit Analog Front-End for Biopotential Measurements datasheet
PDF, 2.5 Mb, Revision: K, File published: Aug 7, 2015
Extract from the document

Prices

Status

ADS1296RIZXGRADS1296RIZXGT
Lifecycle StatusActive (Recommended for new designs)Active (Recommended for new designs)
Manufacture's Sample AvailabilityYesNo

Packaging

ADS1296RIZXGRADS1296RIZXGT
N12
Pin6464
Package TypeZXGZXG
Industry STD TermNFBGANFBGA
JEDEC CodeS-PBGA-NS-PBGA-N
Package QTY1000250
CarrierLARGE T&RSMALL T&R
Device MarkingADS1296RADS1296R
Width (mm)88
Length (mm)88
Thickness (mm)1.011.01
Pitch (mm).8.8
Max Height (mm)1.451.45
Mechanical DataDownloadDownload

Parametrics

Parameters / ModelsADS1296RIZXGR
ADS1296RIZXGR
ADS1296RIZXGT
ADS1296RIZXGT
# Input Channels66
Analog Voltage AVDD(Max), V5.255.25
Analog Voltage AVDD(Min), V2.72.7
ArchitectureDelta-SigmaDelta-Sigma
Digital Supply(Max), V3.63.6
Digital Supply(Min), V1.651.65
INL(Max), +/-LSB88
Input Range(Max), V5.255.25
Input TypeDifferential,Single-EndedDifferential,Single-Ended
Integrated FeaturesDaisy-Chainable,GPIO,Oscillator,PGADaisy-Chainable,GPIO,Oscillator,PGA
InterfaceSPISPI
Multi-Channel ConfigurationSimultaneous SamplingSimultaneous Sampling
Operating Temperature Range, C-40 to 85-40 to 85
Package GroupNFBGANFBGA
Package Size: mm2:W x L, PKG64NFBGA: 64 mm2: 8 x 8(NFBGA)64NFBGA: 64 mm2: 8 x 8(NFBGA)
Power Consumption(Typ), mW5.35.3
RatingCatalogCatalog
Reference ModeInt,ExtInt,Ext
Resolution, Bits2424
SNR, dB112112
Sample Rate (max), SPS32KSPS32KSPS
Sample Rate(Max), MSPS0.0320.032
THD(Typ), dB-98-98

Eco Plan

ADS1296RIZXGRADS1296RIZXGT
RoHSCompliantCompliant

Application Notes

  • Thermal Noise Analysis in ECG Applications
    PDF, 114 Kb, File published: May 3, 2011
    This article discusses the thermal noise source of electrocardiogram (ECG) applications basedon the ADS1298 and ADS1298R family of multichannel, simultaneous sampling, 24-bit, delta-sigma (О”ОЈ) analog-to-digital converters (ADCs). This report offers several observations on identifying the major sources of thermal noise in an ECG system, and makes several recommendations regarding how to improve t
  • Respiration Rate Measurement Using Impedance Pneumography
    PDF, 697 Kb, File published: Mar 1, 2011
    This document discusses the use of impedance pneumography as a technique to measure respiration rate. The generation of high-frequency ac current source is described, and the issues related to delay in modulated signal and finite transition times of carriers are addressed. The report also includesdescriptions of potential implementations of a respiration rate measurement system using the ADS1298
  • Improving Common-Mode Rejection Using the Right-Leg Drive Amplifier
    PDF, 297 Kb, File published: Jul 6, 2011
    This article discusses the need to improve common-mode rejection (CMR) in electrocardiogram (ECG) subsystem applications. Several different techniques to improve CMR while also considering both patient and operator safety are presented. This report also reviews the implementation of the right-leg drive (RLD) loop technique to improve CMR using the ADS129x family of analog-to-digital converters (in
  • Analog Front-End Design for ECG Systems Using Delta-Sigma ADCs (Rev. A)
    PDF, 191 Kb, Revision: A, File published: Apr 13, 2010
    This document discusses the characteristics of electrocardiogram (ECG) signals and different front-endapproaches for ECG signal acquisition. The tradeoffs between different approaches and the effects on overall system design are discussed. The report also includes descriptions of potential implementations of the front-end architecture using the ADS1258 and ADS1278 and respective noise measuremen
  • Analog-to-Digital Converter Grounding Practices Affect System Performance (Rev. A)
    PDF, 69 Kb, Revision: A, File published: May 18, 2015
  • A Glossary of Analog-to-Digital Specifications and Performance Characteristics (Rev. B)
    PDF, 425 Kb, Revision: B, File published: Oct 9, 2011
    This glossary is a collection of the definitions of Texas Instruments' Delta-Sigma (О”ОЈ), successive approximation register (SAR), and pipeline analog-to-digital (A/D) converter specifications and performance characteristics. Although there is a considerable amount of detail in this document, the product data sheet for a particular product specification is the best and final reference.
  • Principles of Data Acquisition and Conversion (Rev. A)
    PDF, 132 Kb, Revision: A, File published: Apr 16, 2015

Model Line

Series: ADS1296R (2)

Manufacturer's Classification

  • Semiconductors> Data Converters> Analog-to-Digital Converters (ADCs)> Precision ADCs (<=10MSPS)
EMS supplier