Datasheet Texas Instruments TAS5756M

ManufacturerTexas Instruments
SeriesTAS5756M
Datasheet Texas Instruments TAS5756M

Digital Input, Closed-Loop Class-D Amplifier with HybridFlow Processing and BD Modulation

Datasheets

TAS5756M Digital Input, Closed-Loop Class-D Amplifier With Processing datasheet
PDF, 3.7 Mb, Revision: B, File published: Aug 6, 2015
Extract from the document

Prices

Status

TAS5756MDCATAS5756MDCAR
Lifecycle StatusActive (Recommended for new designs)Active (Recommended for new designs)
Manufacture's Sample AvailabilityNoYes

Packaging

TAS5756MDCATAS5756MDCAR
N12
Pin4848
Package TypeDCADCA
Industry STD TermHTSSOPHTSSOP
JEDEC CodeR-PDSO-GR-PDSO-G
Package QTY402000
CarrierTUBELARGE T&R
Device MarkingTAS5756MTAS5756M
Width (mm)6.16.1
Length (mm)12.512.5
Thickness (mm)1.151.15
Pitch (mm).5.5
Max Height (mm)1.21.2
Mechanical DataDownloadDownload

Parametrics

Parameters / ModelsTAS5756MDCA
TAS5756MDCA
TAS5756MDCAR
TAS5756MDCAR
Analog Supply (V), Max4.54.5
Audio Input TypeDigitalDigital
Closed/Open LoopClosedClosed
Control InterfaceSoftwareSoftware
Operating Temperature Range, C-25 to 85-25 to 85
Package GroupHTSSOPHTSSOP
Package Size: mm2:W x L, PKG48HTSSOP: 101 mm2: 8.1 x 12.5(HTSSOP)48HTSSOP: 101 mm2: 8.1 x 12.5(HTSSOP)
Power Stage Supply(Max), V26.426.4
Power Stage Supply(Min), V4.54.5
Power to Bridge Tied Load(Max), W4040
Power to Parallel Bridge Tied Load(Max), W7575
RatingCatalogCatalog
Sampling Rate(Max), kHz192192
Sampling Rate(Min), kHz88
Speaker Channels, Max22
Supported Bridge Tied Load(Min), Ohms33

Eco Plan

TAS5756MDCATAS5756MDCAR
RoHSCompliantCompliant

Application Notes

  • TAS57xx Dynamic Range Control
    PDF, 324 Kb, File published: Jun 18, 2010
    This application report provides background information, general equations, and instructions for proper use of the Texas Instruments TAS57xx series Dynamic Range Control (DRC). Topics include I2C configuration, single-band and dual-band DRC, coefficient computation, device offerings, and user interface configuration.
  • AN-1737 Managing EMI in Class D Audio Applications (Rev. A)
    PDF, 140 Kb, Revision: A, File published: May 1, 2013
    Electromagnetic interference (EMI) is an unwanted disturbance caused in an electrical circuit byelectromagnetic radiation emitted from an external source. The disturbance may interrupt, obstruct, orotherwise degrade the effective performance of the circuit.
  • AN-1849 An Audio Amplifier Power Supply Design (Rev. B)
    PDF, 1.9 Mb, Revision: B, File published: May 1, 2013
    This application report provides design information for a power supply for use with our newest offering of high-performance, ultra high-fidelity audio amplifier input stage ICs.
  • Guidelines for Measuring Audio Power Amplifier Performance
    PDF, 765 Kb, File published: Oct 30, 2001
    This application note provides guidelines for measuring the date sheet parameters of Texas Instruments audio power amplifiers (APAs) using prefabricated evaluation modules (EVMs). The primary equipment used for the measurements consists of the System Two audio measurement system by Audio Precision , a digital multimeter (DMM), and a dc power supply.

Model Line

Series: TAS5756M (2)

Manufacturer's Classification

  • Semiconductors> Audio> Mid-Power Audio Amplifiers (5-50W)> Digital I2S Input Class-D
EMS supplier