Datasheet Texas Instruments ADS122U04IPW

ManufacturerTexas Instruments
SeriesADS122U04
Part NumberADS122U04IPW

24-Bit, 2kSPS, 4-Ch, Low-Power Delta-Sigma ADC With PGA, Vref, 2x IDACs, and UART Interface 16-TSSOP -40 to 125

Datasheets

ADS122U04 24-Bit, 4-Channel, 2-kSPS, Delta-Sigma ADC With UART Interface datasheet
PDF, 2.1 Mb, Revision: A, File published: Aug 16, 2017
Extract from the document

Prices

Status

Lifecycle StatusActive (Recommended for new designs)
Manufacture's Sample AvailabilityNo

Packaging

Pin16
Package TypePW
Industry STD TermTSSOP
JEDEC CodeR-PDSO-G
Package QTY90
CarrierTUBE
Device MarkingADS122U
Width (mm)4.4
Length (mm)5
Thickness (mm)1
Pitch (mm)0.65
Max Height (mm)1.2
Mechanical DataDownload

Parametrics

Analog Voltage AVDD(Max)5.5 V
Analog Voltage AVDD(Min)2.3 V
ArchitectureDelta-Sigma
Digital Supply(Max)5.5 V
Digital Supply(Min)2.3 V
Features50/60 Hz Rejection,Excitation Current Sources (iDACs),GPIO,Oscillator,PGA,Temp Sensor,Small Size
Input Range(Max)2.85,5.6 V
Input Range(Min)-2.85,0 V
Input TypeDifferential,Single-Ended
InterfaceUART
Multi-Channel ConfigurationMultiplexed
Number of input channels4
Operating Temperature Range-40 to 125 C
Package GroupTSSOP|16,WQFN|16
Package Size: mm2:W x L16TSSOP: 22 mm2: 4.4 x 5 (TSSOP|16),16WQFN: 9 mm2: 3 x 3 (WQFN|16) PKG
Power Consumption(Typ)1.4 mW
RatingCatalog
Reference ModeExt,Int
Resolution24 Bits
Sample Rate(Max)2 MSPS

Eco Plan

RoHSCompliant

Design Kits & Evaluation Modules

  • Evaluation Modules & Boards: ADS122U04EVM
    ADS122U04 Evaluation Module
    Lifecycle Status: Active (Recommended for new designs)

Application Notes

  • Low-Cost Single-Chip Diff Temp Measurement Solution Using Delta-Sigma ADCs (Rev. A)
    PDF, 486 Kb, Revision: A, File published: May 4, 2018
  • Reducing System Cost Size and Power in Isolated DAQ Systems Using ADS122U04 (Rev. A)
    PDF, 763 Kb, Revision: A, File published: Jun 15, 2017
  • A Basic Guide to Thermocouple Measurements
    PDF, 298 Kb, File published: Sep 28, 2018
    Thermocouples are common temperature sensors used in a wide variety of commercial and industrialapplications. While slightly less accurate than resistance temperature detectors (RTDs) thermocouplescover a wide temperature range are self-powered and have a fast response time. Their simpleconstruction make them inexpensive and durable. Because of the small sensor voltage and low noiserequ
  • A Basic Guide to RTD Measurements
    PDF, 333 Kb, File published: Jun 19, 2018
    RTDs or resistance temperature detectors are sensors used to measure temperature. These sensors arethe among the most accurate temperature sensors available covering large temperature ranges.However getting accurate measurements with precision analog-to-digital converters (ADCs) requiresattention to detail in design of measurement circuits and calculation of the measurement. This applica
  • Digital Filter Types in Delta-Sigma ADCs
    PDF, 219 Kb, File published: Jun 27, 2017
    This application report discusses digital filters which are a ubiquitous feature in delta-sigma analog todigital converters (ADCs). Digital low-pass filters are essential to the functionality of a delta-sigma ADCwhich relies on oversampling and noise shaping to push quantization noise out of band. There arevariations between the types of digital filters used in delta-sigma ADCs that provide