RadioLocman.com Electronics ru
Advanced Search +
  

Datasheet Intersil ISL71091SEH20

ManufacturerIntersil
SeriesISL71091SEH20

2.048V Radiation Hardened Ultra Low Noise, Precision Voltage Reference

Datasheets

  • Download » Datasheet, PDF, 1.3 Mb, Revision: 2017-11-07
    ISL71091SEH20 Datasheet
    Docket ↓
    DATASHEET
    ISL71091SEH20 FN8632
    Rev 2.00
    March 17, 2016 2.048V Radiation Hardened Ultra Low Noise, Precision Voltage Reference
    The ISL71091SEH20 is an ultra low noise, high DC accuracy
    precision voltage reference with a wide input voltage range
    from 4.2V to 30V. It uses Intersil’s advanced bipolar technology
    to achieve 3.8µVP-P 0.1Hz to 10Hz noise with an initial voltage
    accuracy of 0.05%. Features The ISL71091SEH20 offers a 2.048V output voltage option
    with 6ppm/°C temperature coefficient and also provides
    excellent line and load regulation. The device is offered in an
    8 Ld flatpack package. Output voltage noise 3.8µVP-P typical (0.1Hz to 10Hz) The ISL71091SEH20 is ideal for high-end instrumentation,
    data acquisition and processing applications requiring high DC
    precision where low noise performance is critical. Output current capability . 10mA/-5mA Applications Reference output voltage . .2.048V ±0.05% Accuracy over temperature . ±0.15% Accuracy over radiation ±0.25% Supply current . 300µA (typical) VOS temperature coefficient 6ppm/°C maximum Line regulation 5ppm/V maximum Load regulation (Sourcing) . 40ppm/mA maximum Operating temperature range . .-55°C to +125°C Precision voltage sources for data acquisition system for
    space application Strain and pressure gauge for space applications Radiation hardened PWM requiring precision outputs Radiation environment
    -High dose rate (50 to 300rad(Si)/s) . 100krad(Si)
    -Low dose rate (0.01rad(Si)/s) . 100krad(Si)*
    -SEL/SEB free (VCC = 36V) 86MeVcm2/mg
    *Product capability established by initial characterization. The
    “EH” version is acceptance tested on a wafer-by-wafer basis to
    50krad(Si) at low dose rate. Related Literature AN1906, “ISL71091SEHxxEV1Z User’s Guide” AN1938, “Single Event Effects (SEE) Testing of the
    ISL71091SEHxx Precision Voltage References Family” Electrically screened to SMD 5962-14208 AN1939, “Total Dose Testing of the ISL71091SEHxx
    Precision Voltage Reference” ISL71091SEH20 2 VIN ...

Prices

Packaging

Parametrics

ISL71091SEHF20/PROTOISL71091SEHVF20ISL71091SEHVX20
ISL71091SEHF20/PROTOISL71091SEHVF20
ClassV, /PROTOV, /PROTOV, /PROTO
DLA SMD5962-142085962-142085962-14208
Description2.048V Radiation Hardened Ultra Low Noise, Precision Voltage Reference2.048V Radiation Hardened Ultra Low Noise, Precision Voltage Reference2.048V Radiation Hardened Ultra Low Noise, Precision Voltage Reference
High Dose Rate (HDR) krad(Si)100100100
Low Dose Rate (ELDRS) krad(Si)100100100
Operating Temperature Range-55 to 125-55 to 125-55 to 125
Qualification LevelQML Class V (space)QML Class V (space)QML Class V (space)
SEL (MeV/mg/cm2)868686