Electronics ru
Advanced Search +

Datasheet Intersil CD40193BMS


CMOS Presettable Up/Down Counter (Dual Clock With Reset)


  • Download » Datasheet, PDF, 380 Kb, Revision: 2017-12-22
    CD40192BMS, CD40193BMS Datasheet
    Docket ↓
    CD40192BMS, CD40193BMS FN3363
    Rev 0.00
    December 1992 CMOS Presettable Up/Down Counters(Dual Clock With Reset) Features Description CD40192BMS -BCD Type CD40192BMS Presettable BCD Up/Down Counter and the
    CD40193BMS Presettable Binary Up/Down Counter each consist of 4 synchronously clocked, gated “D” type flip-flops connected as a counter. The inputs consist of 4 individual jam lines,
    a PRESET ENABLE control, individual CLOCK UP and
    CLOCK DOWN signals and a master RESET. Four buffered Q
    signal outputs as well as CARRY and BORROW outputs for
    multiple-stage counting schemes are provided. CD40193BMS -Binary Type High Voltage Type (20V Rating) Individual Clock Lines for Counting Up or Counting
    Down Synchronous High-Speed Carry and Borrow Propagation Delays for Cascading Asynchronous Reset and Preset Capability Medium Speed Operation
    -fCL = 8MHz (typ.) at 10V 5V, 10V and 15V Parametric Ratings Standardize Symmetrical Output Characteristics 100% Tested for Quiescent Current at 20V Maximum Input Current of 1A at 18V Over Full Package Temperature Range; 100nA at 18V and +25oC Noise Margin (Over Full Package/Temperature Range)
    -1V at VDD = 5V
    -2V at VDD = 10V
    -2.5V at VDD = 15V Meets All Requirements of JEDEC Tentative Standard
    No. 13B, “Standard Specifications for Description of
    ‘B’ Series CMOS Devices” Applications Up/Down Difference Counting The counter is cleared so that all outputs are in a low state by a
    high on the RESET line. A RESET is accomplished asynchronously with the clock. Each output is individually programmable
    asynchronously with the clock to the level on the corresponding
    jam input when the PRESET ENABLE control is low.
    The counter counts up one count on the positive clock edge of
    the CLOCK UP signal provided the CLOCK DOWN line is high.
    The counter counts down one count on the positive clock edge
    of the CLOCK DOWN signal provided the CLOCK UP line is ...




DLA SMD5962-966085962-966085962-96608
DescriptionCMOS Presettable Up/Down Counter (Dual Clock With Reset)CMOS Presettable Up/Down Counter (Dual Clock With Reset)CMOS Presettable Up/Down Counter (Dual Clock With Reset)
High Dose Rate (HDR) krad(Si)100100100
Low Dose Rate (ELDRS) krad(Si)ELDRS freeELDRS freeELDRS free
Operating Temperature Range-55 to 125-55 to 125-55 to 125
Qualification LevelQML Class V (space)QML Class V (space)QML Class V (space)
SEL (MeV/mg/cm2)757575

Eco Plan


Moldel Line

Series: CD40193BMS (3)

Manufacturer's Classification

  • Space & Harsh Environment > Rad Hard Digital > RH Counters

Slices ↓