Datasheet LT3653 (Analog Devices) - 3

ManufacturerAnalog Devices
Description1.2A, HV Input Regulator with Output Current Limit for Battery Charger Applications
Pages / Page12 / 3 — ELECTRICAL CHARACTERISTICS. The. denotes the specifi cations which apply …
File Format / SizePDF / 146 Kb
Document LanguageEnglish

ELECTRICAL CHARACTERISTICS. The. denotes the specifi cations which apply over the full operating

ELECTRICAL CHARACTERISTICS The denotes the specifi cations which apply over the full operating

Model Line for this Datasheet

Text Version of Document

LT3653
ELECTRICAL CHARACTERISTICS The
l
denotes the specifi cations which apply over the full operating temperature range, otherwise specifi cations are at TA = 25°C; VIN = 12V, VBOOST = 17V, VSW = 0V, RILIM = 33.2k, unless otherwise noted. PARAMETER CONDITIONS MIN TYP MAX UNITS
VC Clamp Voltage VOUT = 0V 1.75 V Switch Peak Current Limit (Note 4) 2 A Switch VCESAT ISW = 1A 275 mV Boost Diode Drop IDIODE = 60mA 0.9 1.2 V Boost Pin Current ISW = 1A 28 mA HVOK Output Voltage High IHVOK = 1mA l 4 4.4 5 V HVOK Output Voltage Low IHVOK = –2μA l 0.25 V
Note 1:
Stresses beyond those listed under Absolute Maximum Ratings
Note 3:
Absolute Maximum Voltage at VIN pin is 60V for non-repetitive may cause permanent damage to the device. Exposure to any Absolute 1 second transients. Maximum Rating condition for extended periods may affect device
Note 4:
Switch Peak Current Limit guaranteed by design and/or correlation reliability and lifetime. to static test.
Note 2:
The LT3653E is guaranteed to meet performance specifi cations
Note 5:
This IC includes overtemperature protection that is intended from 0°C to 125°C. Specifi cations over the –40°C to 125°C operating to protect the device during momentary overload conditions. Junction temperature range are assured by design, characterization, and correlation temperature will exceed the maximum operating junction temperature with statistical process controls. The LT3653I specifi cations are when overtemperature protection is active. Continuous operation above guaranteed over the full –40°C to 125°C temperature range. High junction the specifi ed maximum operating junction temperature may impair device temperatures degrade operating lifetimes. Operating lifetime is derated at reliability. junction temperatures greater than 125°C. 3653f 3
EMS supplier