VOT8123AB, VOT8123AD, VOT8123AG. ABSOLUTE MAXIMUM RATINGS. PARAMETER. TEST CONDITION. SYMBOL. VALUE. UNIT. INPUT. OUTPUT. COUPLER. Note

VOT8123AB, VOT8123AD, VOT8123AG ABSOLUTE MAXIMUM RATINGS PARAMETER TEST CONDITION SYMBOL VALUE UNIT INPUT OUTPUT COUPLER Note

Model Line for this Datasheet

Text Version of Document

VOT8123AB, VOT8123AD, VOT8123AG
www.vishay.com Vishay Semiconductors
ABSOLUTE MAXIMUM RATINGS
(Tamb = 25 °C, unless otherwise specified)
PARAMETER TEST CONDITION SYMBOL VALUE UNIT INPUT
Reverse voltage VR 6 V Forward current IF 50 mA Power dissipation Pdiss 120 mW Junction temperature Tj 125 °C
OUTPUT
Peak off-state voltage VDRM 800 V On-state current IT(RMS) 100 mA Peak repetitive surge current PW = 1 ms, 120 pps ITSM 1 A Power dissipation Pdiss 300 mW Junction temperature Tj 125 °C
COUPLER
Storage temperature range Tstg -55 to +125 °C Ambient temperature range Tamb -40 to +110 °C Total power dissipation Pdiss 330 mW Soldering temperature For 10 s Tsld 260 °C
Note
• Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. Functional operation of the device is not implied at these or any other conditions in excess of those given in the operational sections of this document. Exposure to absolute maximum ratings for extended periods of the time can adversely affect reliability. This phototriac should not be used to drive a load directly. It is intended to be a trigger device only Axis Title Axis Title 60 10000 120 10000 ) A A (m 50 100 rrent u 40 1000 Current (m 80 1000 ard tate C ne ne ne ine ne ine 30 60 Forw 1st li 2nd li On-S 1st li 2nd l 2nd l 2nd li um um 20 100 40 100 im im ax ax M M - 10 - 20 x. x. a a I F m I T m 0 10 0 10 -40 -20 0 20 40 60 80 100 120 -40 -20 0 20 40 60 80 100 120 T - Ambient Temperature (°C) T - Ambient Temperature (°C) amb amb Fig. 1 - Maximum Forward Current vs. Ambient Temperature Fig. 2 - Maximum On-State Current vs. Ambient Temperature Rev. 1.1, 29-Oct-2018
2
Document Number: 84926 For technical questions, contact: optocoupleranswers@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
EMS supplier