VPOS = 5 V and TA = 25°C, unless otherwise noted.
Table 1. Parameter Test Conditions/Comments Min Typ Max Unit
OVERALL FUNCTION Frequency Range 30 6000 MHz FREQUENCY = 30 MHz Gain 18.5 dB Output 1 dB Compression Point 13.0 dBm Output Third-Order Intercept Δf = 1 MHz, output power (POUT) = −7 dBm per tone 31.2 dBm Noise Figure 3.9 dB FREQUENCY = 140 MHz Gain 18.04 dB vs. Frequency ±10 MHz ±0.04 dB vs. Temperature −40°C ≤ TA ≤ +85°C ±0.3 dB vs. Supply 4.75 V to 5.25 V ±0.05 dB Output 1 dB Compression Point 16.9 dBm Output Third-Order Intercept Δf = 1 MHz, output power (POUT) = −7 dBm per tone 32.0 dBm Noise Figure 3.1 dB FREQUENCY = 350 MHz Gain 17.8 dB vs. Frequency ±10 MHz ±0.01 dB vs. Temperature −40°C ≤ TA ≤ +85°C ±0.3 dB vs. Supply 4.75 V to 5.25 V ±0.06 dB Output 1 dB Compression Point 17.4 dBm Output Third-Order Intercept Δf = 1 MHz, output power (POUT) = −7 dBm per tone 31.2 dBm Noise Figure 3.1 dB FREQUENCY = 700 MHz Gain 17.1 17.6 18.0 dB vs. Frequency ±50 MHz ±0.03 dB vs. Temperature −40°C ≤ TA ≤ +85°C ±0.3 dB vs. Supply 4.75 V to 5.25 V ±0.02 dB Output 1 dB Compression Point 17.4 dBm Output Third-Order Intercept Δf = 1 MHz, output power (POUT) = −7 dBm per tone 33.4 dBm Noise Figure 2.9 dB FREQUENCY = 900 MHz Gain 17.0 17.4 17.8 dB vs. Frequency ±50 MHz ±0.03 dB vs. Temperature −40°C ≤ TA ≤ +85°C ±0.3 dB vs. Supply 4.75 V to 5.25 V ±0.02 dB Output 1 dB Compression Point 17.6 dBm Output Third-Order Intercept Δf = 1 MHz, output power (POUT) = −7 dBm per tone 34.9 dBm Noise Figure 2.9 dB FREQUENCY = 1900 MHz Gain 16.2 16.6 17.0 dB vs. Frequency ±50 MHz ±0.05 dB vs. Temperature −40°C ≤ TA ≤ +85°C ±0.3 dB vs. Supply 4.75 V to 5.25 V ±0.04 dB Output 1 dB Compression Point 15.4 dBm Output Third-Order Intercept Δf = 1 MHz, output power (POUT) = −7 dBm per tone 32.4 dBm Noise Figure 3.4 dB Rev. A | Page 3 of 20 Document Outline Features Functional Block Diagram General Description Revision History Specifications Typical Scattering Parameters (S-Parameters) Absolute Maximum Ratings Thermal Resistance ESD Caution Pin Configuration and Function Descriptions Typical Performance Characteristics 500 MHz to 4 GHz Frequency Band 100 MHz to 500 MHz Frequency Band 4 GHz to 6 GHz Frequency Band General Applications Information Basic Connections Soldering Information and Recommended PCB Land Pattern Operation Down to 30 MHz W-CDMA ACPR Performance Evaluation Board Outline Dimensions Ordering Guide
EMS supplier