Datasheet PLF2000 (Posifa Technologies) - 2

ManufacturerPosifa Technologies
DescriptionLiquid Flow Sensor for Water Metering
Pages / Page5 / 2 — PLF2000 Series. SPECIFICATIONS. MIN. TYP. MAX. UNIT. CONDITIONS
File Format / SizePDF / 531 Kb
Document LanguageEnglish

PLF2000 Series. SPECIFICATIONS. MIN. TYP. MAX. UNIT. CONDITIONS

PLF2000 Series SPECIFICATIONS MIN TYP MAX UNIT CONDITIONS

Model Line for this Datasheet

Text Version of Document

PLF2000 Series
LIQUID FLOW SENSOR FOR WATER MONITORING 131 E. Brokaw Road | San Jose CA 95112 | +1 (408) 392-0989 | info@posifatech.com | www.posifatech.com
SPECIFICATIONS
Test Conditions: Vin=5±0.01VDC, Ta=22°C.
SPECIFICATIONS MIN TYP MAX UNIT CONDITIONS
PLF2105 50 700 ml/min PLF2135 100 10000 ml/min Output Count (calibrated) 409 to 3686 count Null Count (calibrated) 380 440 count Output Count (raw) 30000 to 45000 count Output (calibrated) 0.5 to 4.5 VDC Flow Repeatability 0.5 % F.S. Flow Response Time1 5 ms Warm Up Time 5 sec Operating Pressure 50 psi Operating Temperature 5 75 °C Storage Temperature 5 80 °C Supply Voltage 5 5.5 VDC Supply Current 15 mA at 5 VDC supply Wetted Materials NSF/ANSI 61 compliant nylon, silicone and food grade conformal coating Notes: 1. 10% to 90% rise time of the flow sensor to electrically respond to any mass flow change. May be affected by the pneumatic interface. 200410 - Datasheet_PLF2000_LiquiDFLowsensor_rev1_C4 | aPr 2020 | PaGe 2 oF 5 131 e. BroKaw roaD | san Jose Ca 95112 | usa teL. +1-650-646-5788 www.PosiFateCh.CoM | eMaiL: inFo@PosiFateCh.CoM
EMS supplier