Datasheet ADuM5401, ADuM5402, ADuM5403, ADuM5404 (Analog Devices) - 10

ManufacturerAnalog Devices
DescriptionQuad-Channel, 2.5 kV Isolators with Integrated DC-to-DC Converter
Pages / Page29 / 10 — ADuM5401/ADuM5402/ADuM5403/ADuM5404. Data Sheet. PACKAGE CHARACTERISTICS. …
RevisionE
File Format / SizePDF / 457 Kb
Document LanguageEnglish

ADuM5401/ADuM5402/ADuM5403/ADuM5404. Data Sheet. PACKAGE CHARACTERISTICS. Table 14. Parameter Symbol. Min. Typ. Max. Unit. Test

ADuM5401/ADuM5402/ADuM5403/ADuM5404 Data Sheet PACKAGE CHARACTERISTICS Table 14 Parameter Symbol Min Typ Max Unit Test

Model Line for this Datasheet

Text Version of Document

link to page 21 link to page 10 link to page 12 link to page 26 link to page 17 link to page 18
ADuM5401/ADuM5402/ADuM5403/ADuM5404 Data Sheet PACKAGE CHARACTERISTICS Table 14. Parameter Symbol Min Typ Max Unit Test Conditions/Comments
RESISTANCE AND CAPACITANCE Resistance (Input-to-Output)1 RI-O 1012 Ω Capacitance (Input-to-Output)1 CI-O 2.2 pF f = 1 MHz Input Capacitance2 CI 4.0 pF IC Junction-to-Ambient Thermal θJA 45 °C/W Thermocouple located at center of package underside, Resistance test conducted on 4-layer board with thin traces3 1 This device is considered a 2-terminal device; Pin 1 through Pin 8 are shorted together, and Pin 9 through Pin 16 are shorted together. 2 Input capacitance is from any input data pin to ground. 3 See the Thermal Analysis section for thermal model definitions.
REGULATORY INFORMATION
The ADuM5401/ADuM5402/ADuM5403/ADuM5404 are approved by the organizations listed in Table 15. Refer to Table 20 and the Insulation Lifetime section for more information about the recommended maximum working voltages for specific cross-insulation waveforms and insulation levels.
Table 15. UL1 CSA VDE2 CQC
Recognized Under 1577 Component Approved under CSA Component Certified according to IEC Certified by CQC11- Recognition Program1 Acceptance Notice 5A 60747-5-2 (VDE 0884 471543-2012, Part 2):2003-012 GB4943.1-2011 Single Protection, 2500 V rms Testing was conducted per CSA 60950-1-07 Basic insulation, 560 V peak Basic insulation at Isolation Voltage and IEC 60950-1 2nd Ed. at 2.5 kV rated voltage 820 V rms (1159 V peak) Basic insulation at 600 V rms (848 V peak) Reinforced insulation working voltage at 420 V rms (578 V peak), tropical climate, altitude ≤ 5000 meters Reinforced insulation at 250 V rms (353 V peak) working voltage File E214100 File 205078 File 2471900-4880-0001 File CQC16001151347 1 In accordance with UL 1577, each ADuM5401/ADuM5402/ADuM5403/ADuM5404 is proof tested by applying an insulation test voltage ≥ 3000 V rms for 1 second (current leakage detection limit = 10 μA). 2 In accordance with IEC 60747-5-2 (VDE 0884 Part 2):2003-01, each ADuM5401/ADuM5402/ADuM5403/ADuM5404 is proof tested by applying an insulation test voltage ≥ 1590 V peak for 1 second (partial discharge detection limit = 5 pC). The asterisk (*) marking branded on the component designates IEC 60747-5-2 (VDE 0884 Part 2):2003-01 approval.
INSULATION AND SAFETY-RELATED SPECIFICATIONS Table 16. Critical Safety-Related Dimensions and Material Properties Parameter Symbol Value Unit Test Conditions/Comments
Rated Dielectric Insulation Voltage 2500 V rms 1-minute duration Minimum External Air Distance L(I01) 8.0 mm Measured from input terminals to output terminals, shortest distance through air Minimum External Tracking (Creepage) L(I02) 7.6 mm Measured from input terminals to output terminals, shortest distance path along body Minimum Internal Gap (Internal Clearance) 0.017 min mm Distance through insulation Tracking Resistance (Comparative Tracking Index) CTI >175 V DIN IEC 112/VDE 0303, Part 1 Material Group IIIa Material Group (DIN VDE 0110, 1/89, Table 1) Rev. E | Page 10 of 29 Document Outline FEATURES APPLICATIONS GENERAL DESCRIPTION FUNCTIONAL BLOCK DIAGRAMS TABLE OF CONTENTS REVISION HISTORY SPECIFICATIONS ELECTRICAL CHARACTERISTICS—5 V PRIMARY INPUT SUPPLY/5 V SECONDARY ISOLATED SUPPLY ELECTRICAL CHARACTERISTICS—3.3 V PRIMARY INPUT SUPPLY/3.3 V SECONDARY ISOLATED SUPPLY ELECTRICAL CHARACTERISTICS—5 V PRIMARY INPUT SUPPLY/3.3 V SECONDARY ISOLATED SUPPLY PACKAGE CHARACTERISTICS REGULATORY INFORMATION INSULATION AND SAFETY-RELATED SPECIFICATIONS IEC 60747-5-2 (VDE 0884, PART 2):2003-01 INSULATION CHARACTERISTICS RECOMMENDED OPERATING CONDITIONS ABSOLUTE MAXIMUM RATINGS ESD CAUTION PIN CONFIGURATIONS AND FUNCTION DESCRIPTIONS TRUTH TABLE TYPICAL PERFORMANCE CHARACTERISTICS TERMINOLOGY APPLICATIONS INFORMATION PCB LAYOUT THERMAL ANALYSIS PROPAGATION DELAY-RELATED PARAMETERS START-UP BEHAVIOR EMI CONSIDERATIONS DC CORRECTNESS AND MAGNETIC FIELD IMMUNITY POWER CONSUMPTION POWER CONSIDERATIONS INCREASING AVAILABLE POWER INSULATION LIFETIME OUTLINE DIMENSIONS ORDERING GUIDE NOTES NOTES
EMS supplier