ELECTRICAL CHARACTERISTICS
T to T and V = 5V +/-5% unless otherwise noted. MIN MAX CC
PARAMETERS MIN. TYP. MAX. UNITS CONDITIONS POWER REQUIREMENTS
Supply Voltage V +4.75 +5.25 Volts CC Supply Current
SP485
900 µA No Load; RE, DI = 0V or V ; CC DE = VCC 900 µA No Load; RE = 0V, DI = 0V or 5V; DE = 0V
SP483
600 µA No Load; RE, DI = 0V or V ; CC DE = VCC 600 µA No Load; RE = 0V, DI = 0V or 5V; DE = 0V
SP483
10 µA Shutdown Mode; DE = 0V, RE = VCC
ENVIRONMENTAL AND MECHANICAL
Operating Temperature Commercial (_C_) 0 70 ºC Industrial (_E_) -40 +85 ºC Storage Temperature -65 +150 ºC Package: Plastic DIP (_P), NSOIC (_N) 236DSR00 4 Rev. 1.0.3