ADGS5414. Data Sheet. Parameter. +25°C. −40°C to +85°C. −40°C to +125°C. Unit. Test Conditions/Comments

ADGS5414 Data Sheet Parameter +25°C −40°C to +85°C −40°C to +125°C Unit Test Conditions/Comments

Model Line for this Datasheet

Text Version of Document

link to page 19 link to page 19 link to page 19
ADGS5414 Data Sheet Parameter +25°C −40°C to +85°C −40°C to +125°C Unit Test Conditions/Comments
THD + N 0.04 % typ RL = 1 kΩ, 18 V p-p, f = 20 Hz to 20 kHz; see Figure 33 −3 dB Bandwidth 200 MHz typ RL = 50 Ω, CL = 5 pF; see Figure 34 Insertion Loss −0.85 dB typ RL = 50 Ω, CL = 5 pF, f = 1 MHz; see Figure 34 CS (Off ) 11 pF typ VS = 18 V, f = 1 MHz CD (Off ) 11 pF typ VS = 18 V, f = 1 MHz CD (On), CS (On) 26 pF typ VS = 18 V, f = 1 MHz POWER REQUIREMENTS VDD = 39.6 V IDD 80 μA typ All switches open 130 μA max All switches open 80 μA typ All switches closed, VL = 5.5 V 130 μA max All switches closed, VL = 5.5 V 330 μA typ All switches closed, VL = 2.7 V 490 μA max All switches closed, VL = 2.7 V IL Inactive 6.3 μA typ Digital inputs = 0 V or VL 8.0 μA max SCLK = 1 MHz 14 μA typ CS and SDI = 0 V or VL, VL = 5 V 7 μA typ CS and SDI = 0 V or VL, VL = 3 V SCLK = 50 MHz 390 μA typ CS = VL and SDI = 0 V or VL, VL = 5 V 210 μA typ CS = VL and SDI = 0 V or VL, VL = 3 V SDI = 1 MHz 15 μA typ CS and SCLK = 0 V or VL, VL = 5 V 7.5 μA typ CS and SCLK = 0 V or VL, VL = 3 V SDI = 25 MHz 230 μA typ CS and SCLK = 0 V or VL, VL = 5 V 120 μA typ CS and SCLK = 0 V or VL, VL = 3 V Active at 50 MHz 1.8 mA typ Digital inputs toggle between 0 V and VL, VL = 5.5 V 2 2.1 mA max 0.7 mA typ Digital inputs toggle between 0 V and VL, VL = 2.7 V 1.0 mA max Single-Supply Operation (VDD) 9 V min GND = 0 V, VSS = 0 V 40 V max GND = 0 V, VSS = 0 V Rev. 0 | Page 10 of 30 Document Outline FEATURES APPLICATIONS FUNCTIONAL BLOCK DIAGRAM GENERAL DESCRIPTION PRODUCT HIGHLIGHTS TABLE OF CONTENTS REVISION HISTORY SPECIFICATIONS ±15 V DUAL SUPPLY ±20 V DUAL SUPPLY 12 V SINGLE SUPPLY 36 V SINGLE SUPPLY CONTINUOUS CURRENT PER CHANNEL, Sx OR Dx Pins TIMING SPECIFICATIONS Timing Diagrams ABSOLUTE MAXIMUM RATINGS THERMAL RESISTANCE ESD CAUTION PIN CONFIGURATIONS AND FUNCTION DESCRIPTIONS TYPICAL PERFORMANCE CHARACTERISTICS TEST CIRCUITS TERMINOLOGY THEORY OF OPERATION ADDRESS MODE ERROR DETECTION FEATURES CRC Error Detection SCLK Count Error Detection Invalid Read/Write Address Error CLEARING THE ERROR FLAGS REGISTER BURST MODE SOFTWARE RESET DAISY-CHAIN MODE POWER-ON RESET BREAK-BEFORE-MAKE SWITCHING TRENCH ISOLATION APPLICATIONS INFORMATION POWER SUPPLY RAILS POWER SUPPLY RECOMMENDATIONS REGISTER SUMMARY REGISTER DETAILS SWITCH DATA REGISTER ERROR CONFIGURATION REGISTER ERROR FLAGS REGISTER BURST ENABLE REGISTER SOFTWARE RESET REGISTER OUTLINE DIMENSIONS ORDERING GUIDE
EMS supplier