Datasheet RV4L (Vishay) - 3

ManufacturerVishay
DescriptionLong Life / Heavy Duty Potentiometer
Pages / Page5 / 3 — RV4L. STANDARD RESISTANCE ELEMENT DATA. STANDARD. LINEAR TAPER. …
File Format / SizePDF / 114 Kb
Document LanguageEnglish

RV4L. STANDARD RESISTANCE ELEMENT DATA. STANDARD. LINEAR TAPER. RESISTANCE. VALUES. MAX. POWER AT 70 °C. MAX. WORKING VOLTAGE

RV4L STANDARD RESISTANCE ELEMENT DATA STANDARD LINEAR TAPER RESISTANCE VALUES MAX POWER AT 70 °C MAX WORKING VOLTAGE

Model Line for this Datasheet

Text Version of Document

RV4L
www.vishay.com Vishay Sfernice
STANDARD RESISTANCE ELEMENT DATA STANDARD LINEAR TAPER RESISTANCE VALUES MAX. POWER AT 70 °C MAX. WORKING VOLTAGE MAX. CUR. THROUGH ELEMENT WIPER
Ω
W V mA
500 2 31.6 53.2 1K 2 44.7 44.7 2K 2 53.2 31.6 5K 2 100 20.00 10K 2 141 14.14 20K 2 200 10.00 50K 2 315 6.32 100K 2 447 4.47 200K 1 500 2.50 500K 0.50 500 1.00 1M 0.25 500 0.50 2M 0.13 500 0.25 5M 0.05 500 0.10
MECHANICAL SPECIFICATIONS
Mechanical travel 300° ± 5° Operating torque / typical value 2 Ncm (2.83 oz.-inch) End stop torque 70 Ncm max. (6.5 lb-inch max.) Tightening torque of mounting nut 200 Ncm max. (17.3 lb-inch max.) Unit weight 23 g to 32 g max. (0.82 oz. to 1.14 oz.)
ENVIRONMENTAL SPECIFICATIONS
Temperature range -55 °C to +125 °C Climatic category 55/125/10 Sealing Fully sealed - container IP 67
OPTIONS
Length is measured from the mounting surface to the free end of the shaft. The screwdriver slot is aligned with the wiper within ± 10°. Special shafts are available, in accordance to drawings supplied Special feature command shaft by customers. We recommend that customers should not machine tool shafts, in order to avoid damage. Bending or torsion of terminals should also be avoided. 3 Ø 2 RV4L LPRP - with locating peg 12.5 9.2
MARKING
• Vishay trademark • Full ordering information (see Ordering Information table) • Manufacturing date • Marking of terminals 1, 2, 3 Revision: 18-Sep-2024
3
Document Number: 50079 For technical questions, contact: sferpottrimmers@vishay.com THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000