Datasheet MLX75305 (Melexis) - 8

ManufacturerMelexis
DescriptionLight-to-voltage SensorEyeC
Pages / Page12 / 8 — MLX75305. 10. Timing diagrams. 11. Applications Information
File Format / SizePDF / 900 Kb
Document LanguageEnglish

MLX75305. 10. Timing diagrams. 11. Applications Information

MLX75305 10 Timing diagrams 11 Applications Information

Model Line for this Datasheet

Text Version of Document

MLX75305
Datasheet
10. Timing diagrams
E Vdd Unstable V Stable V dd dd E >1mW/cm² e Vdd t t V t OUT t t on off V setup OUT 0.9VOUT 1.05V 0.5V OUT V =0.5V OUT 0.95V OUT dd OUT 0.1VOUT t t Definition of the electrical setup-time t t f r Definition of the rise and fall times Figure 4
11. Applications Information
A typical connection diagram is shown in the figure below. A load resistor RL is needed to get the voltage level out. The load capacitance CL is typically formed by the input capacitance of the component that is connected to the sensor output, the wiring capacitance and the output capacitance of the sensor itself. Vdd Ee 3 MLX75305 2 OUT 1 R C L L Figure 5 Decoupling capacitors between Vdd and Vss (1uF in parallel with 100nF) are highly recommended in all configurations. Recommendation: every change in the application should be agreed by both parties. REVISION 9 - OCTOBER 17, 2016 Page 8 of 12 [390107530501]