TABLE I. Electrical performance characteristics – Continued. 1/ Test Symbol Conditions Temperature, Device Limits Unit VS = 2.5 V, VCM = VS/2 TA type unless otherwise specified Min Max Input characteristics – continued. Input resistance, RINDM +25C 01 225 typical k differential mode Input resistance, RINCM +25C 01 1 typical G common mode Input capacitance, CINDM +25C 01 15 typical pF differential mode Input capacitance, CINCM +25C 01 30 typical pF common mode Output characteristics Output voltage high VOH RL = 10 k to VCM +25C 01 2.49 V 2.495 typical -55C to +125C 2.485 RL = 2 k to VCM +25C 2.46 2.48 typical -55C to +125C 2.44 Output voltage low VOL RL = 10 k to VCM +25C 01 10 mV 5 typical -55C to +125C 15 RL = 2 k to VCM +25C 40 20 typical -55C to +125C 60 Short circuit current ISC +25C 01 30 typical mA Closed loop output ZOUT f = 1 kHz, AV = +10 +25C 01 0.1 typical impedance See footnote at end of table. DLA LAND AND MARITIME SIZE CODE IDENT NO. DWG NO. COLUMBUS, OHIOA16236V62/16615 REV PAGE 6