Datasheet AD822 (Analog Devices) - 5

ManufacturerAnalog Devices
DescriptionSingle-Supply, Rail-to-Rail Low Power FET-Input Dual Op Amp
Pages / Page17 / 5 — DLA LAND AND MARITIME. COLUMBUS, OHIO. 16236. V62/12636
File Format / SizePDF / 101 Kb
Document LanguageEnglish

DLA LAND AND MARITIME. COLUMBUS, OHIO. 16236. V62/12636

DLA LAND AND MARITIME COLUMBUS, OHIO 16236 V62/12636

Model Line for this Datasheet

Text Version of Document

TABLE I. Electrical performance characteristics. 1/ Test Symbol Conditions Temperature, Device Limits Unit VS = 0 V, 5 V, TA type VCM = 0 V, VOUT = 0.2 V, Min Max unless otherwise specified DC performance. Initial offset voltage VIO +25C 01 0.8 mV -55C to +125C 1.2 Initial offset voltage VIO -55C to +125C 01 2 typical V/ drift C Input bias current IIB VCM = 0 V to 4 V +25C 01 25 pA -55C to +125C 6 nA Input offset current IIO +25C 01 20 pA -55C to +125C 0.5 typical nA Open loop gain AO VOUT = 0.2 V to 4 V, RL = 100 k +25C 01 500 V/mV -55C to +125C 400 VOUT = 0.2 V to 4 V, RL = 10 k +25C 80 -55C to +125C 80 VOUT = 0.2 V to 4 V, RL = 1 k +25C 15 -55C to +125C 10 Noise/harmonic performance. Input voltage noise NV f = 0.1 Hz to 10 Hz +25C 01 2 typical Vpp f = 10 Hz 25 typical nV / Hz f = 100 Hz 21 typical f = 1 kHz 16 typical f = 10 kHz 13 typical Input current noise NI f = 0.1 Hz to 10 Hz +25C 01 18 typical fApp f = 1 kHz 0.8 typical fA / Hz Harmonic distortion VOUT = 0.25 V to 4.75 V, +25C 01 -93 typical dB f = 10 kHz, RL = 10 k to 2.5 V See footnotes at end of table.
DLA LAND AND MARITIME
SIZE

CODE IDENT NO. DWG NO.
COLUMBUS, OHIO A 16236 V62/12636
REV A PAGE 5
EMS supplier