Datasheet AD822 (Analog Devices) - 10

ManufacturerAnalog Devices
DescriptionSingle-Supply, Rail-to-Rail Low Power FET-Input Op Amp
Pages / Page24 / 10 — AD822. Data Sheet. ABSOLUTE MAXIMUM RATINGS Table 4. THERMAL RESISTANCE. …
RevisionJ
File Format / SizePDF / 529 Kb
Document LanguageEnglish

AD822. Data Sheet. ABSOLUTE MAXIMUM RATINGS Table 4. THERMAL RESISTANCE. Parameter Rating. Table 5. Thermal Resistance

AD822 Data Sheet ABSOLUTE MAXIMUM RATINGS Table 4 THERMAL RESISTANCE Parameter Rating Table 5 Thermal Resistance

Model Line for this Datasheet

Text Version of Document

link to page 18 link to page 14
AD822 Data Sheet ABSOLUTE MAXIMUM RATINGS Table 4. THERMAL RESISTANCE Parameter Rating
θJA is specified for the worst case conditions, that is, a device Supply Voltage ±18 V soldered in a circuit board for surface-mount packages. Internal Power Dissipation
Table 5. Thermal Resistance
8-Lead PDIP (N) Observe derating curves
Package Type θ
8-Lead SOIC_N (R) Observe derating curves
JA Unit
8-Lead MSOP (RM) Observe derating curves 8-lead PDIP (N) 90 °C/W Input Voltage1 ((V+) + 0.2 V) to 8-lead SOIC_N (R) 160 °C/W ((V−) − 20 V) 8-lead MSOP (RM) 190 °C/W Output Short-Circuit Duration Indefinite Differential Input Voltage ±30 V
MAXIMUM POWER DISSIPATION
Storage Temperature Range (N) –65°C to +125°C The maximum power that can be safely dissipated by the AD822 is Storage Temperature Range (R, RM) –65°C to +150°C limited by the associated rise in junction temperature. For plastic Operating Temperature Range packages, the maximum safe junction temperature is 145°C. If A Grade and B Grade –40°C to +85°C these maximums are exceeded momentarily, proper circuit Lead Temperature 260°C operation is restored as soon as the die temperature is reduced. (Soldering, 60 sec) Leaving the device in the overheated condition for an extended 1 See the Input Characteristics section. period can result in device burnout. To ensure proper operation, it is important to observe the derating curves shown in Figure 27. Stresses at or above those listed under Absolute Maximum Ratings may cause permanent damage to the product. This is a While the AD822 is internally short-circuit protected, this may not stress rating only; functional operation of the product at these be sufficient to guarantee that the maximum junction temperature or any other conditions above those indicated in the operational is not exceeded under all conditions. With power supplies ±12 V or section of this specification is not implied. Operation beyond less at an ambient temperature of 25°C or less, if the output node is the maximum operating conditions for extended periods may shorted to a supply rail, then the amplifier is not destroyed, even if affect product reliability. this condition persists for an extended period.
ESD CAUTION
Rev. J | Page 10 of 24 Document Outline FEATURES APPLICATIONS CONNECTION DIAGRAM GENERAL DESCRIPTION REVISION HISTORY SPECIFICATIONS ABSOLUTE MAXIMUM RATINGS THERMAL RESISTANCE MAXIMUM POWER DISSIPATION ESD CAUTION TYPICAL PERFORMANCE CHARACTERISTICS APPLICATIONS INFORMATION INPUT CHARACTERISTICS OUTPUT CHARACTERISTICS SINGLE-SUPPLY VOLTAGE TO FREQUENCY CONVERTER LOW DROPOUT BIPOLAR BRIDGE DRIVER OUTLINE DIMENSIONS ORDERING GUIDE
EMS supplier