Datasheet TL081, TL081A, TL081B, TL082, TL082A, TL082B, TL084, TL084A, TL084B (Texas Instruments) - 8

ManufacturerTexas Instruments
DescriptionTL08xx JFET-input operational amplifier
Pages / Page51 / 8 — TL081. , TL081A,. TL081B. , TL082,. TL082A. TL082B. , TL084,. TL084A. , …
RevisionI
File Format / SizePDF / 2.5 Mb
Document LanguageEnglish

TL081. , TL081A,. TL081B. , TL082,. TL082A. TL082B. , TL084,. TL084A. , TL084B. www.ti.com. Operating Characteristics (continued). PARAMETER

TL081 , TL081A, TL081B , TL082, TL082A TL082B , TL084, TL084A , TL084B www.ti.com Operating Characteristics (continued) PARAMETER

Text Version of Document

link to page 13
TL081 , TL081A, TL081B , TL082, TL082A TL082B , TL084, TL084A , TL084B
SLOS081I – FEBRUARY 1977 – REVISED MAY 2015
www.ti.com Operating Characteristics (continued)
VCC± = ±15 V, TA= 25°C (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
tr Rise-time 0.05 μs VI = 20 V, RL = 2 kΩ, CL = 100 pF, See Figure 19 overshoot factor 20% f = 1 kHz 18 nV/√Hz Equivalent input noise Vn RS = 20 Ω voltage f = 10 Hz to 10 kHz 4 μV Equivalent input noise In RS = 20 Ω, f = 1 kHz 0.01 pA/√Hz current VIrms = 6 V, AVD = 1, RS ≤ 1 kΩ, RL ≥ 2 kΩ, THD Total harmonic distortion 0.003% f = 1 kHz,
6.8 Dissipation Rating Table TA ≤ 25°C DERATING DERATE TA = 70°C TA = 85°C TA = 125°C PACKAGE POWER RATING FACTOR ABOVE TA POWER RATING POWER RATING POWER RATING
D (14 pin) 680 mW 7.6 mW/°C 60°C 604 m/W 490 mW 186 mW FK 680 mW 11.0 mW/°C 88°C 680 m/W 680 mW 273 mW J 680 mW 11.0 mW/°C 88°C 680 m/W 680 mW 273 mW JG 680 mW 8.4 mW/°C 69°C 672 m/W 546 mW 210 mW 8 Submit Documentation Feedback Copyright © 1977–2015, Texas Instruments Incorporated Product Folder Links: TL081 TL081A TL081B TL082 TL082A TL082B TL084 TL084A TL084B Document Outline 1 Features 2 Applications 3 Description Table of Contents 4 Revision History 5 Pin Configuration and Functions 6 Specifications 6.1 Absolute Maximum Ratings 6.2 ESD Ratings 6.3 Recommended Operating Conditions 6.4 Thermal Information 6.5 Electrical Characteristics for TL08xC, TL08xxC, and TL08xI 6.6 Electrical Characteristics for TL08xM and TL084x 6.7 Operating Characteristics 6.8 Dissipation Rating Table 6.9 Typical Characteristics 7 Parameter Measurement Information 8 Detailed Description 8.1 Overview 8.2 Functional Block Diagram 8.3 Feature Description 8.3.1 Total Harmonic Distortion 8.3.2 Slew Rate 8.4 Device Functional Modes 9 Applications and Implementation 9.1 Application Information 9.2 Typical Applications 9.2.1 Inverting Amplifier Application 9.2.1.1 Design Requirements 9.2.1.2 Detailed Design Procedure 9.2.1.3 Application Curve 9.3 System Examples 9.3.1 General Applications 10 Power Supply Recommendations 11 Layout 11.1 Layout Guidelines 11.2 Layout Examples 12 Device and Documentation Support 12.1 Documentation Support 12.1.1 Related Documentation 12.2 Related Links 12.3 Community Resources 12.4 Trademarks 12.5 Electrostatic Discharge Caution 12.6 Glossary 13 Mechanical, Packaging, and Orderable Information