Datasheet BL8506 (Belling) - 3

ManufacturerBelling
DescriptionHigh-Precision Low Voltage Detector
Pages / Page19 / 3 — BL8506. RECOMMENDED WORK CONDITIONS. ELECTRICAL CHARACTERISTICS. …
File Format / SizePDF / 876 Kb
Document LanguageEnglish

BL8506. RECOMMENDED WORK CONDITIONS. ELECTRICAL CHARACTERISTICS. www.belling.com.cn 3

BL8506 RECOMMENDED WORK CONDITIONS ELECTRICAL CHARACTERISTICS www.belling.com.cn 3

Model Line for this Datasheet

BL8506

Text Version of Document

BL8506 RECOMMENDED WORK CONDITIONS
Item Min Recommended Max Units Input voltage range 0.7 10 V Ambient temperature -40 25 85 C
ELECTRICAL CHARACTERISTICS
BL8506-09C/NXX (0.9V) TA=25C, unless otherwise specified. Reference data Symbol Parameter Conditions Units Min Typ Max -VDET Detector threshold 0.882 0.9 0.918 V Detector threshold VHYS 0.018 0.036 0.054 V hysteresis ISS Current consumption VDD=2.9V 1 2.5 uA Maximum operating VDDH 10 V voltage Minimum operating VDDL 0.5 V voltage Nch VDS=0.05V, VDD=0.7V 0.01 0.05 mA IOUT Output current VDS=0.50V, VDD=0.8V 0.05 0.50 Pch mA VDS=-2.1V, VDD=4.50V 1.0 2.0 TPLH Output delay time 20 us BL8506-25C/NXX (2.5V) TA=25C, unless otherwise specified. Reference data Symbol Parameter Conditions Units Min Typ Max -VDET Detector threshold 2.450 2.5 2.550 V Detector threshold VHYS 0.050 0.100 0.150 V hysteresis ISS Current consumption VDD=4.5V 1 2.5 uA Maximum operating VDDH 10 V voltage Minimum operating VDDL 0.5 V voltage Nch mA V 0.01 0.05 I DS=0.05V, VDD=0.70V OUT Output current Pch mA VDS=-2.1V, VDD=4.50V 1.0 2.0 TPLH Output delay time 20 us
www.belling.com.cn 3