BL8506-27C/NXX (2.7V) TA=25C, unless otherwise specified. Reference data Symbol Parameter Conditions Units Min Typ Max -VDET Detector threshold 2.646 2.7 2.754 V Detector threshold VHYS 0.054 0.108 0.162 V hysteresis ISS Current consumption VDD=4.7V 1 2.5 uA Maximum operating VDDH 10 V voltage Minimum operating VDDL 0.5 V voltage Nch mA V 0.01 0.05 I DS=0.05V, VDD=0.70V OUT Output current Pch mA VDS=-2.1V, VDD=4.50V 1.0 2.0 TPLH Output delay time 20 us BL8506-30C/NXX (3.0V) TA=25C, unless otherwise specified. Reference data Symbol Parameter Conditions Units Min Typ Max -VDET Detector threshold 2.94 3.0 3.06 V Detector threshold VHYS 0.060 0.12 0.18 V hysteresis ISS Current consumption VDD=5.0V 1 2.5 uA Maximum operating VDDH 10 V voltage Minimum operating VDDL 0.5 V voltage Nch mA V 0.01 0.05 I DS=0.05V, VDD=0.7V OUT Output current Pch mA VDS=-2.1V, VDD=4.50V 1.0 2.0 TPLH Output delay time 20 us BL8506-34C/NXX (3.4V) TA=25C, unless otherwise specified. Reference data Symbol Parameter Conditions Units Min Typ Max -VDET Detector threshold 3.332 3.4 3.468 V Detector threshold VHYS 0.068 0.136 0.204 V hysteresis ISS Current consumption VDD=5.4V 1 2.5 uA Maximum operating VDDH 10 V voltage Minimum operating VDDL 0.5 V voltage Nch mA V 0.01 0.05 I DS=0.05V, VDD=0.7V OUT Output current Pch mA VDS=-2.1V, VDD=4.50V 1.0 2.0 TPLH Output delay time 20 us