Datasheet Texas Instruments SN65LBC182DRG4
| Manufacturer | Texas Instruments |
| Series | SN65LBC182 |
| Part Number | SN65LBC182DRG4 |

Half-duplex,15-kV ESD, 1/4 UL Transceiver 8-SOIC -40 to 85
Datasheets
SN65LBC182, SN75LBC182 Differential Bus Transceiver datasheet
PDF, 877 Kb, Revision: A, File published: Mar 25, 2005
Extract from the document
Status
| Lifecycle Status | Active (Recommended for new designs) |
| Manufacture's Sample Availability | No |
Packaging
| Pin | 8 |
| Package Type | D |
| Industry STD Term | SOIC |
| JEDEC Code | R-PDSO-G |
| Package QTY | 2500 |
| Carrier | LARGE T&R |
| Device Marking | 6LB182 |
| Width (mm) | 3.91 |
| Length (mm) | 4.9 |
| Thickness (mm) | 1.58 |
| Pitch (mm) | 1.27 |
| Max Height (mm) | 1.75 |
| Mechanical Data | Download |
Parametrics
| Common Mode Range | -7 to 12 |
| Duplex | Half |
| Fail Safe | Open |
| Fault Protection | -10 to 15 V |
| HBM ESD | 15 kV |
| ICC(Max) | 30 mA |
| IEC 61000-4-2 Contact | 8 +/- kV |
| Isolated | No |
| No. of RX | 1 |
| No. of TX | 1 |
| Number of Nodes | 128 |
| Operating Temperature Range | -40 to 85 C |
| Package Group | SOIC |
| Rating | Catalog |
| Signaling Rate(Max) | 0.25 Mbps |
| Supply Voltage(s)(Nom) | 5 V |
Eco Plan
| RoHS | Compliant |
Design Kits & Evaluation Modules
- Evaluation Modules & Boards: RS485-HF-DPLX-EVM
RS-485 Half-Duplex Evaluation Module
Lifecycle Status: Active (Recommended for new designs)
Application Notes
- RS-485 for E-Meter Applications (Rev. A)PDF, 311 Kb, Revision: A, File published: Aug 6, 2004
This application report discusses the best practices for designing energy meter communication circuits using the RS-485 standard. Component selection and performance tradeoffs are covered with reference to relevant standards such as IEC 61036 and DL/T 645. Reference design details are provided to help energy meter engineers successfully complete their own circuit designs. - The RS-485 Unit Load and Maximum Number of Bus ConnectionsPDF, 197 Kb, File published: Mar 15, 2004
The TIA/EIA-485 (RS-485) standard defines a Unit Load and confines bus configurations to 32. This report explains the Unit-Load concept and how it relates to the maximum number of bus connections. Fractional Unit-Load devices, such at the 1/8th Unit-Load SN65HVD21 and SN65HVD06, allow up to 256 devices on a single bus segment.
Model Line
Series: SN65LBC182 (6)
- SN65LBC182D SN65LBC182DG4 SN65LBC182DR SN65LBC182DRG4 SN65LBC182P SN65LBC182PE4
Manufacturer's Classification
- Semiconductors > Interface > RS-485/RS-422