Datasheet Texas Instruments ISO1050

ManufacturerTexas Instruments
SeriesISO1050
Datasheet Texas Instruments ISO1050

Isolated 5 V CAN Transceiver

Datasheets

ISO1050 Isolated CAN Transceiver datasheet
PDF, 2.0 Mb, Revision: I, File published: Jan 22, 2015
Extract from the document

Prices

Status

ISO1050DUBISO1050DUBRISO1050DWISO1050DWR
Lifecycle StatusActive (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)
Manufacture's Sample AvailabilityYesYesYesYes

Packaging

ISO1050DUBISO1050DUBRISO1050DWISO1050DWR
N1234
Pin881616
Package TypeDUBDUBDWDW
Industry STD TermSOPSOPSOICSOIC
JEDEC CodeR-PDSO-GR-PDSO-GR-PDSO-GR-PDSO-G
Package QTY50350402000
CarrierTUBELARGE T&RTUBELARGE T&R
Device MarkingISO1050ISO1050ISO1050ISO1050
Width (mm)6.576.577.57.5
Length (mm)9.59.510.310.3
Thickness (mm)3.33.32.352.35
Pitch (mm)2.542.541.271.27
Max Height (mm)4.854.852.652.65
Mechanical DataDownloadDownloadDownloadDownload

Parametrics

Parameters / ModelsISO1050DUB
ISO1050DUB
ISO1050DUBR
ISO1050DUBR
ISO1050DW
ISO1050DW
ISO1050DWR
ISO1050DWR
CSA 60601-1 Reinforced Working, Vrms125125125125
CSA 60950-1 Basic Working, Vrms760,730760,730760,730760,730
CSA 60950-1 Reinforced Working, Vrms380,148380,148380,148380,148
CSA 61010-1 Basic Working, Vrms600600600600
CSA 61010-1 Reinforced Working, Vrms300,148300,148300,148300,148
CSA Isolation Rating, Vrms5000,25005000,25005000,25005000,2500
DIN V VDE V 0884-10 Working Voltage, Vpk1.21.21.21.2
DIN V VDE V 0884-10 Transient Overvoltage Rating, Vpk4444
Datarate, Mbps1111
Fault Protection, V-27 to 40-27 to 40-27 to 40-27 to 40
Isolation Rating, Vrms4.24.24.24.2
Operating Temperature Range, C-55 to 105-55 to 105-55 to 105-55 to 105
Package GroupSOPSOPSOICSOIC
Package Size: mm2:W x L, PKG8SOP: 62 mm2: 6.57 x 9.5(SOP)8SOP: 62 mm2: 6.57 x 9.5(SOP)16SOIC: 106 mm2: 10.3 x 10.3(SOIC)16SOIC: 106 mm2: 10.3 x 10.3(SOIC)
Surge Voltage Rating, Vpk4444
TUV EN 60950-1 Basic Working, Vrms400400400400
TUV EN 60950-1 Reinforced Working, Vrms600600600600
TUV EN 61010-1 Basic Working, Vrms400400400400
TUV EN 61010-1 Reinforced Working, Vrms600600600600
TUV Isolation Rating, Vrms5000,25005000,25005000,25005000,2500
UL 1577 Isolation Voltage (Double), Vrms3.5,2.53.5,2.53.5,2.53.5,2.5
VCC1(Max), V5.55.55.55.5
VCC1(Min), V3333
VCC2(Max), V5.255.255.255.25
VCC2(Min), V4.754.754.754.75

Eco Plan

ISO1050DUBISO1050DUBRISO1050DWISO1050DWR
RoHSCompliantCompliantCompliantCompliant

Application Notes

  • Isolated CAN Reference Design (Rev. C)
    PDF, 39 Kb, Revision: C, File published: Sep 14, 2018
    This design note presents the reference design of an isolated CAN node using the isolated CAN transceiver and a transformer driver SN6505A to generate the isolated power.
  • Isolated CAN solution by using ISO1050 and SN6501
    PDF, 406 Kb, File published: Jan 16, 2013
  • Common-Mode Chokes in CAN Networks: Source of Unexpected Transients
    PDF, 230 Kb, File published: Jan 29, 2008
    Common-mode chokes are frequently used in automotive CAN networks to increase system reliability with respect to electromagnetic compatibility (EMC). Electromagnetic interference emitted from an Electronic Control Module (ECU) through the CAN transceiver can be filtered, thus limiting unwanted high-frequency noise on the communication bus. Another reason for using a common-mode choke is attempting
  • Isolated RS-485 Reference Design
    PDF, 80 Kb, File published: Oct 28, 2009
    This design note presents the reference designs of isolated RS-485 nodes, using bus voltages of 3.3 V and 5 V. Various transceivers are used to satisfy the requirements for low, medium, and high data rates, as well as to accommodate the need for half- and full-duplex operation.

Model Line

Manufacturer's Classification

  • Semiconductors> Isolation> Isolated CAN Transceivers
EMS supplier