Datasheet Texas Instruments ISO122

ManufacturerTexas Instruments
SeriesISO122
Datasheet Texas Instruments ISO122

Precision Isolation Amplifier

Datasheets

ISO122 Precision Lowest-Cost Isolation Amplifier datasheet
PDF, 1.0 Mb, Revision: A, File published: Jan 23, 2015
Extract from the document

Prices

Status

ISO122JPISO122JPE4ISO122JUISO122JU/1KISO122JUE4ISO122PISO122PE4ISO122UISO122U/1KISO122U/1KE4ISO122UE4
Lifecycle StatusActive (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)
Manufacture's Sample AvailabilityNoNoNoNoNoNoNoNoNoNoNo

Packaging

ISO122JPISO122JPE4ISO122JUISO122JU/1KISO122JUE4ISO122PISO122PE4ISO122UISO122U/1KISO122U/1KE4ISO122UE4
N1234567891011
Pin88888888888
Package TypeNVFNVFDVADVADVANVFNVFDVADVADVADVA
Industry STD TermPDIPPDIPSOICSOICSOICPDIPPDIPSOICSOICSOICSOIC
JEDEC CodeR-PDIP-TR-PDIP-TR-PDSO-GR-PDSO-GR-PDSO-GR-PDIP-TR-PDIP-TR-PDSO-GR-PDSO-GR-PDSO-GR-PDSO-G
Package QTY2525201000202525201000100020
CarrierTUBETUBETUBELARGE T&RTUBETUBETUBETUBELARGE T&RLARGE T&RTUBE
Device MarkingISO122JPISO122JP122JU122JUISOISO122PISO122PISOISOISOISO
Width (mm)6.616.617.57.57.56.616.617.57.57.57.5
Length (mm)20.0120.0117.917.917.920.0120.0117.917.917.917.9
Thickness (mm)3.943.942.32.32.33.943.942.32.32.32.3
Pitch (mm)2.542.541.271.271.272.542.541.271.271.271.27
Max Height (mm)5.335.332.652.652.655.335.332.652.652.652.65
Mechanical DataDownloadDownloadDownloadDownloadDownloadDownloadDownloadDownloadDownloadDownloadDownload

Parametrics

Parameters / ModelsISO122JP
ISO122JP
ISO122JPE4
ISO122JPE4
ISO122JU
ISO122JU
ISO122JU/1K
ISO122JU/1K
ISO122JUE4
ISO122JUE4
ISO122P
ISO122P
ISO122PE4
ISO122PE4
ISO122U
ISO122U
ISO122U/1K
ISO122U/1K
ISO122U/1KE4
ISO122U/1KE4
ISO122UE4
ISO122UE4
Common Mode Rejection Ratio(Typ), dB140140140140140140140140140140140
Gain Non-Linearity (+/-)(Max), %0.020.020.020.020.020.020.020.020.020.020.02
Isolation Working Voltage VIOWM (rms), V15001500150015001500150015001500150015001500
Leakage Current at 240V/60Hz(Max), uArms0.50.50.50.50.50.50.50.50.50.50.5
Operating Temperature Range, C-25 to 85-25 to 85-25 to 85-25 to 85-25 to 85-25 to 85-25 to 85-25 to 85-25 to 85-25 to 85-25 to 85
Package GroupPDIPPDIPSOICSOICSOICPDIPPDIPSOICSOICSOICSOIC
Package Size: mm2:W x L, PKGSee datasheet (PDIP)See datasheet (PDIP)8SOIC: 185 mm2: 10.33 x 17.9(SOIC)8SOIC: 185 mm2: 10.33 x 17.9(SOIC)8SOIC: 185 mm2: 10.33 x 17.9(SOIC)See datasheet (PDIP)See datasheet (PDIP)8SOIC: 185 mm2: 10.33 x 17.9(SOIC)8SOIC: 185 mm2: 10.33 x 17.9(SOIC)8SOIC: 185 mm2: 10.33 x 17.9(SOIC)8SOIC: 185 mm2: 10.33 x 17.9(SOIC)
RatingCatalogCatalogCatalogCatalogCatalogCatalogCatalogCatalogCatalogCatalogCatalog
Small Signal Bandwidth(Typ), kHz5050505050505050505050

Eco Plan

ISO122JPISO122JPE4ISO122JUISO122JU/1KISO122JUE4ISO122PISO122PE4ISO122UISO122U/1KISO122U/1KE4ISO122UE4
RoHSCompliantCompliantCompliantCompliantCompliantCompliantCompliantCompliantCompliantCompliantCompliant
Pb FreeYesYesYesYes

Application Notes

  • Boost ISO120 Bandwidth to More Than 100kHz
    PDF, 55 Kb, File published: Sep 27, 2000
    There has been considerable demand for high-bandwidth isolation amplifiers. The highest bandwidth Burr-Brown ISO amps are the ISO100 and the ISO120/121/122 family with bandwidths of about 50kHz. The ISO120/121 bandwidth can be boosted to more than 100kHz by adding gain in the feedback.
  • Single Supply 4-20mA Current Loop Receiver
    PDF, 29 Kb, File published: Sep 27, 2000
    Many industrial current-loop data acquisition systems operate on a 24V or 28V single supply. You can make a single-supply current loop receiver with the RCV420 by using its 10V reference as a pseudo ground. The RCV420 will convert a 4-20mA loop current into a 0 to 5V output voltage with no external components required. The current loop can be sourcing or sinking and can be referenced to either the
  • Single-Supply Operation of Isolation Amplifiers
    PDF, 46 Kb, File published: Sep 27, 2000
    For simplicity, many systems are designed to operate from a single external power supply. In battery powered systems such as aircraft and automotive, it's often a requirement. Isolation amplifiers such as the ISO120 and ISO122 can be easily modified for input side single-supply operation with the addition of an INA105 difference amplifier. With ISO amps, it's the isolated input side power supply w
  • IC Building Blocks Form Complete Isolated 4-20mA Current-Loop
    PDF, 72 Kb, File published: Sep 27, 2000
    Current loops have become the standard for signal transmission in the process control industry. Current loops are insensitive to noise and are immune to errors from line impedance. Adding isolation to the 4-20mA current loop protects system electronics from electrical noise and transients. It also allows transducers to be electrically separated by hundreds of volts.
  • Simple Output Filter Eliminates ISO Amp Output Ripple And Keeps Full Bandwidth
    PDF, 186 Kb, File published: Sep 27, 2000
    The ISO120/121/122 isolation amplifiers (ISO amps) have a small (10-20mVp-p typ) residual demodulator ripple at the output. A simple filter can be added to eliminate the output ripple without decreasing the 50kHz signal bandwidth of the ISO amp.
  • Noise Sources In Applications Using Capacitive Coupled Isolated Amplifier
    PDF, 101 Kb, File published: Sep 27, 2000
    Noise is a typical problem confronting many isolation applications. Isolation products such as analog isolation amplifiers, optocouplers, transformers and digital couplers, are used in applications to transmit signals across a high voltage barrier while providing galvanic separation between two grounds.
  • Isolated RS-485 Reference Design
    PDF, 80 Kb, File published: Oct 28, 2009
    This design note presents the reference designs of isolated RS-485 nodes, using bus voltages of 3.3 V and 5 V. Various transceivers are used to satisfy the requirements for low, medium, and high data rates, as well as to accommodate the need for half- and full-duplex operation.

Model Line

Manufacturer's Classification

  • Semiconductors> Amplifiers> Special Function Amplifiers> Isolated Amplifiers
EMS supplier