Datasheet Texas Instruments PGA900

ManufacturerTexas Instruments
SeriesPGA900
Datasheet Texas Instruments PGA900

Programmable Resistive Sensing Conditioner with Digital and Analog Outputs

Datasheets

PGA900 Programmable Resistive Sensing Conditioner with Digital and Analog Outputs datasheet
PDF, 1.7 Mb, Revision: A, File published: May 12, 2015
Extract from the document

Prices

Status

PGA900ARHHRPGA900ARHHTPGA900AYZSR
Lifecycle StatusActive (Recommended for new designs)Active (Recommended for new designs)Preview (Device has been announced but is not in production. Samples may or may not be available)
Manufacture's Sample AvailabilityYesNoNo

Packaging

PGA900ARHHRPGA900ARHHTPGA900AYZSR
N123
Pin363636
Package TypeRHHRHHYZS
Industry STD TermVQFNVQFNDSBGA
JEDEC CodeS-PQFP-NS-PQFP-NS-XBGA-N
Package QTY25002501500
CarrierLARGE T&RSMALL T&R
Device MarkingPGA900APGA900APGA900A
Width (mm)66
Length (mm)66
Thickness (mm).9.9.4
Pitch (mm).5.5.5
Max Height (mm)11.625
Mechanical DataDownloadDownloadDownload

Parametrics

Parameters / ModelsPGA900ARHHR
PGA900ARHHR
PGA900ARHHT
PGA900ARHHT
PGA900AYZSR
PGA900AYZSR
# Input Channels222
InterfaceSPI, UART, I2C, PWM, OWI, Ratiometric Analog Voltage, 4-20mASPI, UART, I2C, PWM, OWI, Ratiometric Analog Voltage, 4-20mASPI, UART, I2C, PWM, OWI, Ratiometric Analog Voltage, 4-20mA
Operating Temperature Range, C-40 to 150-40 to 150-40 to 150
Package GroupVQFNVQFNDSBGA
Package Size: mm2:W x L, PKG36VQFN: 36 mm2: 6 x 6(VQFN)36VQFN: 36 mm2: 6 x 6(VQFN)See datasheet (DSBGA)
RatingCatalogCatalogCatalog
Resolution, Bits242424
Sample Rate (max), SPS15.6k15.6k15.6k
Vs(Max), V303030
Vs(Min), V3.33.33.3

Eco Plan

PGA900ARHHRPGA900ARHHTPGA900AYZSR
RoHSCompliantCompliantCompliant

Application Notes

  • Understanding Open Loop Gain of the PGA900 DAC Gain Amplifier
    PDF, 338 Kb, File published: Apr 2, 2015
    The open-loop gain (AOL) of an operational amplifier is one of the most important specifications. Proper understanding of AOL at DC and over frequency is crucial for the understanding of closed-loop gain, bandwidth, and stability analysis.This application note provides an in-depth understanding of the PGA900 AOL magnitude and phase over frequency. The effects of
  • Connecting PGA900 Instrumentation Amplifier to Resistive Bridge Sensor
    PDF, 1.1 Mb, File published: May 8, 2015
    Understanding the input and output limitations of an instrumentation amplifier (IA) is important in interfacing a resistive bridge sensor to the PGA900. Adjusting the common mode voltage of the input signal appropriately allows us to maximize the gain. Maximizing the gain yields the largest output signal span for the 24-bit analog-to-digital converter (ADC). The largest signal span maximizes the c
  • Understanding Open Loop Output Impedance of the PGA900 DAC Gain Amplifier (Rev. A)
    PDF, 253 Kb, Revision: A, File published: May 19, 2015
    The open-loop output impedance (ZO) of an operational amplifier is one of the most important specifications. Proper understanding of ZO over frequency is crucial for the understanding of loop gain, bandwidth, and stability analysis.This application note provides an in-depth understanding of the PGA900 ZO magnitude over frequency. The effects of temperature, power
  • PGA900 as 4- to 20-mA Current Loop Transmitter
    PDF, 238 Kb, File published: May 7, 2015
    This application note shows the PGA900 used as a 2-wire, 4- to 20-mA current loop transmitter, a common method of transmitting sensor information in industrial process-monitoring applications. Transmitting sensor information (physical parameter measurements) through a current loop is particularly useful when the information must be sent to a remote location over long distances (1000 feet or more).
  • PGA900 DAC Output Stability Application Note
    PDF, 253 Kb, File published: Mar 4, 2015
    Capacitive load drive is one of the most common causes of operational amplifier stability issues. The load capacitance, CL, interacts with the open-loop output impedance of the amplifier, ZO, by adding a single or double pole in the open-loop response. The additional pole or poles degrades the circuit phase margin, resulting in transient overshoot and ringing, ac gain peaking
  • System Noise Analysis of a Resistive Bridge Pressure Sensor Connected to the PGA
    PDF, 195 Kb, File published: Jul 7, 2015
    In this application note we will do a system noise analysis of the PGA900 connected to a resistive bridgepressure sensor. First, we will measure the noise referred to the output for the PGA900. Then, using these measurement results we will calculate the noise-free resolution and effective resolution of the PGA900 forits analog-to-digital converter operating at 64- and 128-Вµs output data
  • Ratiometric measurement in the context of LVDT-sensor signal conditioning
    PDF, 228 Kb, File published: Jul 21, 2016
  • Design tips for a resistive-bridge pressure sensor in industrial process-control
    PDF, 240 Kb, File published: Jul 24, 2015
  • Analog Applications Journal 3Q 2015
    PDF, 7.1 Mb, File published: Jul 24, 2015

Model Line

Manufacturer's Classification

  • Semiconductors> Sensing Products> Resistive Bridge Sensor Signal Conditioners
EMS supplier