Datasheet Texas Instruments INA110AG

ManufacturerTexas Instruments
SeriesINA110
Part NumberINA110AG
Datasheet Texas Instruments INA110AG

Datasheets

Fast-Settling FET-Input Instrumentation Amp datasheet
PDF, 501 Kb, Revision: A, File published: Jul 21, 2005
Extract from the document

Prices

Status

Lifecycle StatusNRND (Not recommended for new designs)
Manufacture's Sample AvailabilityNo

Packaging

Pin16
Package TypeZZ109
Industry STD TermZZ (BB)
JEDEC CodeR-CDIP-T
Mechanical DataDownload

Replacements

ReplacementINA110KP
Replacement CodeP

Parametrics

Approx. Price (US$)7.96 | 1ku
Bandwidth at Min Gain(Typ)(MHz)2.5
CMRR(Min)(dB)106
Gain Error (+/-)(Max)(%)0.5
Gain Non-Linearity (+/-)(Max)(%)0.01
Gain(Max)(V/V)1000
Gain(Min)(V/V)1
Input Bias Current (+/-)(Max)(nA)0.05
Input Offset (+/-)(Max)(uV)250
Input Offset Drift (+/-)(Max)(uV/C)2
Iq(Typ)(mA)3
Noise at 0.1 Hz - 10 Hz(Typ)(uVpp)1
Noise at 1kHz(Typ)(nV/rt(Hz))10
Number of Channels(#)1
Operating Temperature Range(C)-55 to 125
Package GroupPDIP
SOIC
Package Size: mm2:W x L (PKG)See datasheet (PDIP)
See datasheet (CDIP SB)
RatingCatalog
Vs(Max)(V)36
Vs(Min)(V)12

Eco Plan

RoHSNot Compliant
Pb FreeNo

Application Notes

  • AC Coupling Instrumentation and Difference Amplifiers
    PDF, 38 Kb, File published: Sep 27, 2000