APPLICATIONS INFORMATION Table 7. FAULT1 Register (04h): Read/Write. BIT. REGISTER NAME. OPERATION. DEFAULT

APPLICATIONS INFORMATION Table 7 FAULT1 Register (04h): Read/Write BIT REGISTER NAME OPERATION DEFAULT

Model Line for this Datasheet

Text Version of Document

LTC2946
APPLICATIONS INFORMATION Table 7. FAULT1 Register (04h): Read/Write BIT REGISTER NAME OPERATION DEFAULT
F1[7] POWER Overvalue Fault POWER > Maximum POWER Threshold 0 [1] = POWER Overvalue Fault Occurred [0] = No POWER Overvalue Fault Occurred F1[6] POWER Undervalue Fault POWER < Minimum POWER Threshold 0 [1] = POWER Undervalue Fault Occurred [0] = No POWER Undervalue Fault Occurred F1[5] ISENSE Overvalue Fault ISENSE > Maximum ISENSE Threshold 0 [1] = ISENSE Overvalue Fault Occurred [0] = No ISENSE Overvalue Fault Occurred F1[4] ISENSE Undervalue Fault ISENSE < Minimum ISENSE Threshold 0 [1] = ISENSE Undervalue Fault Occurred [0] = No ISENSE Undervalue Fault Occurred F1[3] VIN Overvalue Fault VIN > Maximum VIN Threshold 0 [1] = VIN Overvalue Fault Occurred [0] = No VIN Overvalue Fault Occurred F1[2] VIN Undervalue Fault VIN < Minimum VIN Threshold 0 [1] = VIN Undervalue Fault Occurred [0] = No VIN Undervalue Fault Occurred F1[1] ADIN Overvalue Fault ADIN > Maximum ADIN Threshold 0 [1] = ADIN Overvalue Fault Occurred [0] = No ADIN Overvalue Fault Occurred F1[0] ADIN Undervalue Fault ADIN < Minimum ADIN Threshold 0 [1] = ADIN Undervalue Fault Occurred [0] = No ADIN Undervalue Fault Occurred
Table 8. ALERT2 Register (32h): Read/Write BIT REGISTER NAME OPERATION DEFAULT
AL2[7] ADC Conversion Done Alert Alert When ADC Finishes a Conversion 0 [1] = Enable [0] = Disable AL2[6] GPIO1 Input Alert Alert if 0 GPIO1 Is Low When GP[7:6] = [01] (GPIO1 Input Active Low), or GPIO1 Is High When GP[7:6] = [00] (GPIO1 Input Active High) [1] = Enable Alert [0] = Disable Alert AL2[5] GPIO2 Input Alert Alert if 0 GPIO2 Is Low When GP[5:4] = [01] (GPIO2 Input Active Low), or GPIO2 Is High When GP[5:4] = [00] (GPIO2 Input Active High) [1] = Enable Alert [0] = Disable Alert AL2[4] Reserved 0 AL2[3] Stuck-Bus Timeout Wake-Up Alert Alert if Part Exits Shutdown Mode After Stuck-Bus Timer Expires with CB[4] = 1 0 [1] = Enable Alert [0] = Disable Alert AL2[2] Energy Overflow Alert Alert if Energy Register Overflow 0 [1] = Enable Alert [0] = Disable Alert 2946fa For more information www.linear.com/LTC2946 29 Document Outline Features Applications Description Typical Application Absolute Maximum Ratings Pin Configuration Order Information Electrical Characteristics Typical Performance Characteristics Pin Functions Block Diagram Timing Diagram Operation Applications Information Typical Applications Package Description Typical Application Related Parts