Datasheet AD604 (Analog Devices) - 4

ManufacturerAnalog Devices
DescriptionDual, Ultralow Noise Variable Gain Amplifier
Pages / Page32 / 4 — AD604. Parameter. Conditions. Min. Typ. Max. Unit
RevisionG
File Format / SizePDF / 741 Kb
Document LanguageEnglish

AD604. Parameter. Conditions. Min. Typ. Max. Unit

AD604 Parameter Conditions Min Typ Max Unit

Model Line for this Datasheet

Text Version of Document

AD604 Parameter Conditions Min Typ Max Unit
ACCURACY Absolute Gain Error 0 dB to 3 dB 0.25 V < VGN < 0.400 V −1.2 +0.75 +3 dB 3 dB to 43 dB 0.400 V < VGN < 2.400 V −1.0 ±0.3 +1.0 dB 43 dB to 48 dB 2.400 V < VGN < 2.65 V −3.5 −1.25 +1.2 dB Gain Scaling Error 0.400 V < VGN < 2.400 V ±0.25 dB/V Output Offset Voltage VREF = 2.500 V, VOCM = 2.500 V −50 ±30 +50 mV Output Offset Variation VREF = 2.500 V, VOCM = 2.500 V 30 50 mV GAIN CONTROL INTERFACE Gain Scaling Factor VREF = 2.5 V, 0.4 V < VGN < 2.4 V 19 20 21 dB/V VREF = 1.67 V 30 dB/V Gain Range Preamplifier gain = 14 dB 0 to 48 dB Preamplifier gain = 20 dB 6 to 54 dB Input Voltage (VGN) Range 20 dB/V, VREF = 2.5 V 0.1 to 2.9 V Input Bias Current −0.4 μA Input Resistance 2 MΩ Response Time 48 dB gain change 0.2 μs VREF Input Resistance 10 kΩ POWER SUPPLY Specified Operating Range One complete channel ±5 V One DSX only 5 V Power Dissipation One complete channel 220 mW One DSX only 95 mW Quiescent Supply Current VPOS, one complete channel 32 36 mA VPOS, one DSX only 19 23 mA VNEG, one preamplifier only −15 −12 mA Powered Down VPOS, VGN < 50 mV, one channel 1.9 3.0 mA VNEG, VGN < 50 mV, one channel −150 μA Power-Up Response Time 48 dB gain change, VOUT = 2 V p-p 0.6 μs Power-Down Response Time 0.4 μs Rev. G | Page 4 of 32 Document Outline FEATURES APPLICATIONS GENERAL DESCRIPTION FUNCTIONAL BLOCK DIAGRAM TABLE OF CONTENTS REVISION HISTORY SPECIFICATIONS ABSOLUTE MAXIMUM RATINGS ESD CAUTION PIN CONFIGURATION AND FUNCTION DESCRIPTIONS TYPICAL PERFORMANCE CHARACTERISTICS THEORY OF OPERATION PREAMPLIFIER DIFFERENTIAL LADDER (ATTENUATOR) AC COUPLING GAIN CONTROL INTERFACE ACTIVE FEEDBACK AMPLIFIER (FIXED-GAIN AMP) APPLICATIONS INFORMATION ULTRALOW NOISE AGC AMPLIFIER WITH 82 dB TO 96 dB GAIN RANGE ULTRALOW NOISE, DIFFERENTIAL INPUT-DIFFERENTIAL OUTPUT VGA MEDICAL ULTRASOUND TGC DRIVING THE AD9050, A 10-BIT, 40 MSPS ADC EVALUATION BOARD CONNECTING A WAVEFORM TO THE AD604-EVALZ DSX INPUT CONNECTIONS Cascade VGAs to Boost Gain PREAMPLIFIER GAIN OUTPUTS DC OPERATING CONDITIONS EVALUATION BOARD ARTWORK AND SCHEMATIC OUTLINE DIMENSIONS ORDERING GUIDE
EMS supplier