ADA4558. Data Sheet. Parameter. Symbol. Test Conditions/Comments. Min. Typ. Max. Unit

ADA4558 Data Sheet Parameter Symbol Test Conditions/Comments Min Typ Max Unit

Model Line for this Datasheet

Text Version of Document

ADA4558 Data Sheet Parameter Symbol Test Conditions/Comments Min Typ Max Unit
EXTERNAL TEMPERATURE SENSOR Valid Temperature Range −50 +165 °C External Temperature Sensor Two calibration points using a PT1000 −0.5 +0.5 °C Accuracy sensor One calibration point using a PT1000 −2 +2 °C sensor Gain Setting Accuracy −2 ±0.2 +2 % LIN INPUT AND OUTPUT STAGE Compliant with LIN Specification 2.1 Voltage Voltage range over which LIN is 6 18 V functional Baud Rate 1 20 kbps Current Limit for Driver (LIN Bus ILIN_DOM_MAX Pulled to maximum VDD12 40 200 mA Dominant State) Driver Off ILIN_PASS_REC 8 V < VDD12 < 18 V, VLIN ≥ VDD12 20 μA Input Leakage ILIN_PAS_DOM VLIN = 0 V −1 mA LIN Pin Current While Ground Disconnected ILIN_NO_GND VDD12 = 12 V, control unit −1 +1 mA disconnected from ground While Battery Disconnected ILIN_NO_BAT VDD12 disconnected, 0 V < VLIN < 18 V 30 μA LIN Receiver Dominant State VLIN_DOM 40 % VDD12 Recessive State VLIN_REC 60 % VDD12 Center Voltage VLIN_CNT 47.5 50 52.5 % VDD12 Hysteresis Voltage VHYS 17.5 % VDD12 Slave Termination Resistance RSLAVE 21 25 34 kΩ LIN RECEIVER TIMING PARAMETERS Propagation Delay of Receiver tRX_PD 6 µs Symmetry of Receiver Propagation tRX_SYM Rising edge with the respect to falling −2 +2 µs Delay edge LIN DRIVER TIMING PARAMETERS Bus load conditions (CBUS, RBUS): 1 nF and 1 kΩ; 6.8 nF and 660 Ω; 10 nF and 500 Ω Duty Cycle 1 D1 For proper operation at 20 kbps 0.396 Duty Cycle 2 D2 For proper operation at 20 kbps 0.581 Duty Cycle 3 D3 For proper operation at 10.4 kbps 0.417 Duty Cycle 4 D4 For proper operation at 10.4 kbps 0.590 ADC Measurement Time To valid reading 120 µs LIN SLEEP/WAKE-UP Force sleep mode by sending a diagnostic master request frame (frame identifier = 0x3C, with the first data byte equal to 0x00); sleep mode is also entered if there is no activity on the LIN bus for a certain time Auto Sleep Enable Time Wake-up occurs if a recessive to 4 sec dominant transition on the LIN bus is followed by a dominant level on the LIN bus maintained for a certain time (minimum dominant time), followed by a dominant to recessive transition; the dominant to recessive transition wakes up the device Minimum Dominant Time 150 µs Rev. 0 | Page 4 of 12 Document Outline FEATURES APPLICATIONS GENERAL DESCRIPTION FUNCTIONAL BLOCK DIAGRAM TABLE OF CONTENTS REVISION HISTORY SPECIFICATIONS ABSOLUTE MAXIMUM RATINGS THERMAL RESISTANCE ESD CAUTION PIN CONFIGURATION AND FUNCTION DESCRIPTIONS TYPICAL PERFORMANCE CHARACTERISTICS THEORY OF OPERATION APPLICATIONS INFORMATION TYPICAL CONNECTION DIAGRAM EMC PERFORMANCE PCB LAYOUT GUIDELINES OUTLINE DIMENSIONS ORDERING GUIDE AUTOMOTIVE PRODUCTS
EMS supplier