Datasheet MP2307 (Monolithic Power Systems) - 5

ManufacturerMonolithic Power Systems
Description3A, 23V, 340KHz Synchronous Rectified Step-Down Converter
Pages / Page12 / 5 — MP2307 – 3A, 23V, 340KHz SYNCHRONOUS RECTIFIED STEP-DOWN CONVERTER. PIN …
File Format / SizePDF / 713 Kb
Document LanguageEnglish

MP2307 – 3A, 23V, 340KHz SYNCHRONOUS RECTIFIED STEP-DOWN CONVERTER. PIN FUNCTIONS. Pin #. Name Description

MP2307 – 3A, 23V, 340KHz SYNCHRONOUS RECTIFIED STEP-DOWN CONVERTER PIN FUNCTIONS Pin # Name Description

Model Line for this Datasheet

Text Version of Document

MP2307 – 3A, 23V, 340KHz SYNCHRONOUS RECTIFIED STEP-DOWN CONVERTER PIN FUNCTIONS Pin # Name Description
High-Side Gate Drive Boost Input. BS supplies the drive for the high-side N-Channel MOSFET 1 BS switch. Connect a 0.01µF or greater capacitor from SW to BS to power the high side switch. Power Input. IN supplies the power to the IC, as well as the step-down converter switches. 2 IN Drive IN with a 4.75V to 23V power source. Bypass IN to GND with a suitably large capacitor to eliminate noise on the input to the IC. See Input Capacitor. Power Switching Output. SW is the switching node that supplies power to the output. Connect 3 SW the output LC filter from SW to the output load. Note that a capacitor is required from SW to BS to power the high-side switch. 4 GND Ground (Connect the exposed pad to Pin 4). Feedback Input. FB senses the output voltage and regulates it. Drive FB with a resistive 5 FB voltage divider connected to it from the output voltage. The feedback threshold is 0.925V. See Setting the Output Voltage. Compensation Node. COMP is used to compensate the regulation control loop. Connect a 6 COMP series RC network from COMP to GND. In some cases, an additional capacitor from COMP to GND is required. See Compensation Components. Enable Input. EN is a digital input that turns the regulator on or off. Drive EN high to turn on 7 EN the regulator; low to turn it off. Attach to IN with a 100kΩ pull up resistor for automatic startup. Soft-Start Control Input. SS controls the soft-start period. Connect a capacitor from SS to GND 8 SS to set the soft-start period. A 0.1µF capacitor sets the soft-start period to 15ms. To disable the soft-start feature, leave SS unconnected. MP2393 O RECOMMENDED FOR NEW DESIGNS NOT REFER T MP2307 Rev. 1.9 www.MonolithicPower.com
5
5/28/2008 MPS Proprietary Information. Unauthorized Photocopy and Duplication Prohibited. © 2008 MPS. All Rights Reserved.
EMS supplier