Datasheet ADCMP371-KGD (Analog Devices) - 3

ManufacturerAnalog Devices
DescriptionGeneral Purpose Comparators
Pages / Page6 / 3 — Known Good Die. ADCMP371-KGD. SPECIFICATIONS. Table 1. Parameter. Min. …
File Format / SizePDF / 136 Kb
Document LanguageEnglish

Known Good Die. ADCMP371-KGD. SPECIFICATIONS. Table 1. Parameter. Min. Typ. Max. Unit. Test Conditions/Comments

Known Good Die ADCMP371-KGD SPECIFICATIONS Table 1 Parameter Min Typ Max Unit Test Conditions/Comments

Model Line for this Datasheet

Text Version of Document

Known Good Die ADCMP371-KGD SPECIFICATIONS
VCC = full operating range, TA = −40°C to +85°C, unless otherwise noted.
Table 1. Parameter Min Typ Max Unit Test Conditions/Comments
SUPPLY VCC Operating Voltage Range 2.25 5.5 V Supply Current 4 7 µA COMMON-MODE INPUT RANGE 0 VCC V INPUT OFFSET VOLTAGE 9 mV VIN = VCC/2 INPUT OFFSET VOLTAGE AVERAGE DRIFT 5 µV/°C VCM = 0 V INPUT BIAS CURRENT 50 nA VIN = VCC/2 INPUT OFFSET CURRENT 150 nA VIN = VCC/2 OUT VOLTAGE LOW 0.4 V IN+ < IN−, ISINK = 1.2 mA OUT VOLTAGE HIGH 0.8 VCC V IN+ > IN−, ISOURCE = 500 µA Output Rise Time 30 ns COUT = 15 pF Output Fall Time 45 ns COUT = 15 pF TIMING Propagation Delay 5 µs Input overdrive = 10 mV 2 µs Input overdrive = 100 mV Rev. 0 | Page 3 of 6 Document Outline FEATURES APPLICATIONS GENERAL DESCRIPTION FUNCTIONAL BLOCK DIAGRAM TABLE OF CONTENTS REVISION HISTORY SPECIFICATIONS ABSOLUTE MAXIMUM RATINGS ESD CAUTION PIN CONFIGURATION AND FUNCTION DESCRIPTIONS OUTLINE DIMENSIONS DIE SPECIFICATIONS AND ASSEMBLY RECOMMENDATIONS ORDERING GUIDE