Datasheet ADN4624 (Analog Devices) - 6

ManufacturerAnalog Devices
Description5.7 kV RMS, Quad-Channel LVDS 2.5 Gigabit Isolator
Pages / Page20 / 6 — ADN4624. SPECIFICATIONS. REGULATORY INFORMATION. Table 6. RN-28-1 Wide …
File Format / SizePDF / 3.5 Mb
Document LanguageEnglish

ADN4624. SPECIFICATIONS. REGULATORY INFORMATION. Table 6. RN-28-1 Wide Body with Finer Pitch [SOIC_W_FP] Package

ADN4624 SPECIFICATIONS REGULATORY INFORMATION Table 6 RN-28-1 Wide Body with Finer Pitch [SOIC_W_FP] Package

Model Line for this Datasheet

Text Version of Document

link to page 8 link to page 18 link to page 6 link to page 6 link to page 6 link to page 7 Data Sheet
ADN4624 SPECIFICATIONS REGULATORY INFORMATION
See Table 10 and the Insulation Lifetime section for details regarding the recommended maximum working voltages for specific cross-isolation waveforms and insulation levels.
Table 6. RN-28-1 Wide Body with Finer Pitch [SOIC_W_FP] Package Regulatory Agency Standard Certification/Approval File
UL (Pending) To be recognized under UL 1577 Component Recognition Program1 E214100 Single protection, 5700 V rms isolation voltage CSA (Pending)2 To be approved under CSA Component Acceptance Notice 5A 205078 CSA 62368-1-19, EN 62368-1:2020 and IEC 62368-1:2018 third edition Basic insulation at 830 V rms Reinforced insulation at 415 V rms CSA 61010-1-12+A1 and IEC 61010-1 third edition Basic insulation at 600 V rms Reinforced insulation at 300 V rms CSA 60601-1:14 and IEC60601-1 third edition+A1 2 means of patient protection (MOPP) for 261 V rms VDE (Pending) To be certified according to DIN V VDE V 0884-11 (VDE V 0884-11):2017-013 2471900-4880-0001 Reinforced insulation, VIORM = 849 VPEAK, VIOSM = 8000 VPEAK CQC (Pending) To be certified according to GB4943.1-2011 per CQC11-471543-2015 Pending Basic insulation at 820 V rms (1159 VPEAK) Reinforced insulation at 410 V rms (578 VPEAK) 1 In accordance with UL 1577, each ADN4624 is proof tested by applying an insulation test voltage ≥ 6840 V rms for 1 sec. 2 Working voltages are quoted for Pollution Degree 2, Material Group III. ADN4624 case material has been evaluated by CSA as Material Group I. 3 In accordance with DIN V VDE V 0884-11, each ADN4624 is proof tested by applying an insulation test voltage ≥ 1592 VPEAK for 1 sec (partial discharge detection limit = 5 pC).
DIN V VDE V 0884-11 (VDE V 0884-11) INSULATION CHARACTERISTICS (PENDING)
This isolator is suitable for reinforced electrical isolation only within the safety limit data. Protective circuits ensure the maintenance of the safety data.
Table 7. Description Test Conditions/Comments1 Symbol Characteristic Unit
Installation Classification per DIN VDE 0110 For Rated Mains Voltage ≤ 150 V rms I to IV For Rated Mains Voltage ≤ 300 V rms I to IV For Rated Mains Voltage ≤ 600 V rms I to IV Climatic Classification 40/125/21 Pollution Degree per DIN VDE 0110, Table 1 2 Maximum Working Insulation Voltage VIORM 849 VPEAK Input to Output Test Voltage, Method B1 VIORM × 1.875 = VPD (M), 100% production test, tINI = tM = 1 VPD (m) 1592 VPEAK sec, partial discharge < 5 pC Input to Output Test Voltage, Method A VPD (m) After Environmental Tests Subgroup 1 VIORM × 1.5 = VPD (M), tINI = 60 sec, tM = 10 sec, partial 1274 VPEAK discharge < 5 pC After Input or Safety Test Subgroup 2 and Subgroup 3 VIORM × 1.2 = VPD (M), tINI = 60 sec, tM = 10 sec, partial 1019 VPEAK discharge < 5 pC Highest Allowable Overvoltage VIOTM 8000 VPEAK Surge Isolation Voltage Basic VPEAK = 16 kV, 1.2 µs rise time, 50 µs, 50% fall time VIOSM 16,000 VPEAK
analog.com Rev. 0 | 6 of 20
Document Outline Features Applications Functional Block Diagram General Description Specifications Receiver Input Threshold Test Voltages Timing Specifications Insulation and Safety Related Specifications Package Characteristics Regulatory Information DIN V VDE V 0884-11 (VDE V 0884-11) Insulation Characteristics (Pending) Recommended Operating Conditions Absolute Maximum Ratings Thermal Resistance Electrostatic Discharge (ESD) Ratings ESD Ratings for ADN4624 ESD Caution Pin Configuration and Function Descriptions Typical Performance Characteristics Test Circuits and Switching Characteristics Theory of Operation Isolation and Refresh Truth Table Applications Information PCB Layout Application Examples Magnetic Field Immunity Insulation Lifetime Surface Tracking Insulation Wear Out Calculation and Use of Parameters Example Outline Dimensions Ordering Guide Evaluation Boards
EMS supplier