Datasheet AS3935 (ScioSense) - 2

ManufacturerScioSense
DescriptionFranklin Lightning Sensor IC with embedded distance estimation algorithm.
Pages / Page44 / 2 — AS3935. Franklin Lightning Sensor IC. General Description. Key Benefits …
File Format / SizePDF / 1.1 Mb
Document LanguageEnglish

AS3935. Franklin Lightning Sensor IC. General Description. Key Benefits & Features. Figure 1: Added Value of Using AS3935

AS3935 Franklin Lightning Sensor IC General Description Key Benefits & Features Figure 1: Added Value of Using AS3935

Model Line for this Datasheet

Text Version of Document

link to page 39 link to page 44
AS3935 Franklin Lightning Sensor IC
The AS3935 is a programmable fully integrated Lightning
General Description
Sensor IC that detects the presence and approach of potentially hazardous lightning activity in the vicinity and provides an estimation on the distance to the head of the storm. The embedded lightning algorithm checks the incoming signal pattern to reject the potential man-made disturbers. The AS3935 can also provide information on the noise level and inform the external unit (e.g. microcontroller) in case of high noise conditions, with the noise floor generator and noise floor evaluation blocks. The AS3935 can be programmed via a 4-wire standard SPI and is also compatible with I²C. Also, in case the latter is chosen, it is possible to choose among three different addresses. Two clocks are internally generated by two different RC-Oscillators: TRCO and SRCO. An automatic calibration procedure can increase the precision of those oscillators. The AS3935 can be either supplied by an internal voltage regulator or directly by VDD. Ordering Information and Content Guide appear at end of datasheet.
Key Benefits & Features
The benefits and features of AS3935, Franklin Lightning Sensor IC are listed below:
Figure 1: Added Value of Using AS3935 Benefits Features
Lightning sensor warns of lightning storm activity

Advanced warning ahead of human senses within a radius of 40km

Distance estimation to the head of the storm from

Early awareness of approaching storms overhead to 40km in 15 steps

Detects both cloud-to-ground and intra-cloud

Detection of both types of lightning phenomena (cloud-to-cloud) flashes

Reduces false detections

Embedded man-made disturber rejection algorithm

Programmable detection levels enable threshold

Flexibility for various applications setting for optimal controls
ams Datasheet Page 1
[v1-04] 2016-Jan-13 Document Feedback Document Outline ScioSense_Cover_page AS3935 Data Sheet General Description Key Benefits & Features Applications Block Diagram Pin Assignments Absolute Maximum Ratings Electrical Characteristics Operating Conditions DC/AC Characteristics for Digital Inputs and Outputs Detailed System and Block Specification Typical Operating Characteristics Detailed Description Circuit Operating Modes Power-Down Mode Listening Mode Signal Verification System and Block Specification Register Table Register Table Description and Default Value Serial Peripheral Interface (SPI) SPI Command Structure Writing of Register Data Reading of Data from Addressable Registers (READ Mode) Send Direct Command Byte I²C Guideline for Pull Up Resistors on I2CL and I2CD I²C Byte Write I²C Register Read Direct Command Voltage Regulator Analog Front-End (AFE) and Watchdog Noise Floor Level Measurement and Evaluation Lightning Algorithm Signal Validation Energy Calculation Statistical Distance Estimation Interrupt Management Antenna Tuning Clock Generation Noise Sources to Be Avoided Package Drawings & Markings Ordering & Contact Information RoHS Compliant & ams Green Statement Copyrights & Disclaimer Document Status Revision Information Content Guide