Datasheet Texas Instruments OPA2364IDG4

ManufacturerTexas Instruments
SeriesOPA2364
Part NumberOPA2364IDG4
Datasheet Texas Instruments OPA2364IDG4

1.8V, High CMR, RRIO Op Amp 8-SOIC -40 to 125

Datasheets

OPAx363, OPAx364 1.8-V, 7-MHz, 90-dB CMRR, Single-Supply, Rail-to-Rail I/O Operational Amplifier datasheet
PDF, 1.8 Mb, Revision: D, File published: Mar 6, 2016
Extract from the document

Prices

Status

Lifecycle StatusActive (Recommended for new designs)
Manufacture's Sample AvailabilityNo

Packaging

Pin8
Package TypeD
Industry STD TermSOIC
JEDEC CodeR-PDSO-G
Width (mm)3.91
Length (mm)4.9
Thickness (mm)1.58
Pitch (mm)1.27
Max Height (mm)1.75
Mechanical DataDownload

Parametrics

Additional FeaturesShutdown
Approx. Price (US$)1.07 | 1ku
ArchitectureCMOS
CMRR(Min)(dB)74
CMRR(Typ)(dB)90
GBW(Typ)(MHz)7
Input Bias Current(Max)(pA)10
Iq per channel(Max)(mA)0.75
Iq per channel(Typ)(mA)0.65
Number of Channels(#)2
Offset Drift(Typ)(uV/C)3
Operating Temperature Range(C)-40 to 125
Output Current(Typ)(mA)45
Package GroupSOIC
Package Size: mm2:W x L (PKG)8SOIC: 29 mm2: 6 x 4.9(SOIC)
Rail-to-RailIn
Out
RatingCatalog
Slew Rate(Typ)(V/us)5
Total Supply Voltage(Max)(+5V=5, +/-5V=10)5.5
Total Supply Voltage(Min)(+5V=5, +/-5V=10)1.8
Vn at 1kHz(Typ)(nV/rtHz)17
Vos (Offset Voltage @ 25C)(Max)(mV)2.5

Eco Plan

RoHSNot Compliant
Pb FreeNo

Application Notes

  • High-Voltage Signal Conditioning for Differential ADCs
    PDF, 125 Kb, File published: Jun 14, 2004
    Analog designers are frequently required to convert high-voltage signals to levels acceptable to low-voltage data converters with differential inputs. This paper describes solutions for this common task using modern amplifiers and typical power supplies. Three examples of conditioning В±10V bipolar signals for low-voltage analog-to-digital converters (ADCs) are shown: a single-supply design,
  • Tuning in Amplifiers
    PDF, 44 Kb, File published: Oct 2, 2000
    Have you ever had the experience of designing an analog gain block with an amplifier that is specified to be unity gain stable only to find that it is oscillating out of control in your circuit? Or have you ever replaced a stable voltage feedback amplifier with a current feedback amplifier to find that the current feedback amplifier immediately oscillates when placed in the amplifier socket? Oscil
  • Single-Supply Operation of Operational Amplifiers
    PDF, 77 Kb, File published: Oct 2, 2000
    Operation of op amps from single supply voltages is useful when negative supply voltages are not available. Furthermore, certain applications using high voltage and high current op amps can derive important benefits from single supply operation.
  • Op Amp Performance Analysis
    PDF, 76 Kb, File published: Oct 2, 2000
    This bulletin reflects the analysis power gained through knowledge of an op amp circuit's feedback factor. Feedback dictates the performance of an op amp both in function and in quality. The major specifications of the amplifier descibe an open-loop device awaiting feedback direction of the end circuit's function. Just how well the amplifier performs the function reflects through the feedback inte

Model Line

Manufacturer's Classification

  • Semiconductors > Amplifiers > Operational Amplifiers (Op Amps) > Precision Op Amps
EMS supplier