Datasheet Texas Instruments THS6182DWPRG4

ManufacturerTexas Instruments
SeriesTHS6182
Part NumberTHS6182DWPRG4
Datasheet Texas Instruments THS6182DWPRG4

Low Power Dissipation ADSL Line Driver 20-SO PowerPAD -40 to 85

Datasheets

Low Power Dissipation ADSL Line Driver datasheet
PDF, 1.8 Mb, Revision: H, File published: Jun 11, 2007
Extract from the document

Prices

Status

Lifecycle StatusActive (Recommended for new designs)
Manufacture's Sample AvailabilityNo

Packaging

Pin20
Package TypeDWP
Industry STD TermHSOIC
JEDEC CodeR-PDSO-G
Package QTY2000
CarrierLARGE T&R
Device MarkingTHS6182
Width (mm)7.52
Length (mm)12.82
Thickness (mm)2.55
Pitch (mm)1.27
Max Height (mm)2.65
Mechanical DataDownload

Parametrics

2nd Harmonic88 dBc
3rd Harmonic107 dBc
@ MHz1
Acl, min spec gain1 V/V
Additional FeaturesN/A
ArchitectureCurrent FB
BW @ Acl100 MHz
CMRR(Min)48 dB
CMRR(Typ)54 dB
GBW(Typ)100 MHz
Input Bias Current(Max)15000000 pA
Iq per channel(Max)12.5 mA
Iq per channel(Typ)11.5 mA
Number of Channels2
Offset Drift(Typ)50 uV/C
Operating Temperature Range-40 to 85 C
Output Current(Typ)600 mA
Package GroupSO PowerPAD
Package Size: mm2:W x L20SO PowerPAD: 133 mm2: 10.405 x 12.825(SO PowerPAD) PKG
Rail-to-RailNo
RatingCatalog
Slew Rate(Typ)450 V/us
Total Supply Voltage(Max)33 +5V=5, +/-5V=10
Total Supply Voltage(Min)8 +5V=5, +/-5V=10
Vn at 1kHz(Typ)13 nV/rtHz
Vn at Flatband(Typ)3.2 nV/rtHz
Vos (Offset Voltage @ 25C)(Max)20 mV

Eco Plan

RoHSCompliant

Design Kits & Evaluation Modules

  • Evaluation Modules & Boards: THS6182RHFEVM
    THS6182RHF Evaluation Module
    Lifecycle Status: Active (Recommended for new designs)
  • Evaluation Modules & Boards: THS6182DWEVM
    THS6182DW Evaluation Module
    Lifecycle Status: Active (Recommended for new designs)

Application Notes

  • Wireline Data Transmission and Reception
    PDF, 191 Kb, File published: Jan 27, 2010
    Many types of wires are widely used to transmit data. Specifically, Category 3 and Category 5 (Cat3 and Cat5e, respectively)—also known as unshielded twisted pair or UTP lines—are now recommended for new telephone installations. Coaxial (coax) cables are used to distribute cable television (CATV) signals throughout a home. #12 and #14 American wire gauge (AWG) electric power distribution wire is a
  • Noise Analysis for High Speed Op Amps (Rev. A)
    PDF, 256 Kb, Revision: A, File published: Jan 17, 2005
    As system bandwidths have increased an accurate estimate of the noise contribution for each element in the signal channel has become increasingly important. Many designers are not however particularly comfortable with the calculations required to predict the total noise for an op amp or in the conversions between the different descriptions of noise. Considerable inconsistency between manufactu

Model Line

Manufacturer's Classification

  • Semiconductors > Amplifiers > Operational Amplifiers (Op Amps) > High-Speed Op Amps (>=50MHz)
EMS supplier