Datasheet Texas Instruments TLC3541ID

ManufacturerTexas Instruments
SeriesTLC3541
Part NumberTLC3541ID
Datasheet Texas Instruments TLC3541ID

14-Bit 200KSPS ADC Ser. Out, Auto PWRDN, Single Ended Input 8-SOIC -40 to 85

Datasheets

5-V, Low Power, 14-Bit, 200 KSPS, Serial ADC with Auto-Power Down datasheet
PDF, 1.0 Mb, File published: May 23, 2001
Extract from the document

Prices

Status

Lifecycle StatusActive (Recommended for new designs)
Manufacture's Sample AvailabilityYes

Packaging

Pin8
Package TypeD
Industry STD TermSOIC
JEDEC CodeR-PDSO-G
Package QTY75
CarrierTUBE
Device Marking3541I
Width (mm)3.91
Length (mm)4.9
Thickness (mm)1.58
Pitch (mm)1.27
Max Height (mm)1.75
Mechanical DataDownload

Parametrics

# Input Channels1
Analog Voltage AVDD(Max)5.5 V
Analog Voltage AVDD(Min)4.5 V
ArchitectureSAR
Digital Supply(Max)5.5 V
Digital Supply(Min)4.5 V
INL(Max)1 +/-LSB
Input Range(Max)5.5 V
Input TypeSingle-Ended
Integrated FeaturesOscillator
InterfaceSPI
Multi-Channel ConfigurationN/A
Operating Temperature Range-40 to 85 C
Package GroupSOIC
Package Size: mm2:W x L8SOIC: 29 mm2: 6 x 4.9(SOIC) PKG
Power Consumption(Typ)17 mW
RatingCatalog
Reference ModeExt
Resolution14 Bits
SINAD81.5 dB
SNR82 dB
Sample Rate (max)200kSPS SPS
Sample Rate(Max)0.2 MSPS
THD(Typ)-94 dB

Eco Plan

RoHSCompliant

Design Kits & Evaluation Modules

  • Evaluation Modules & Boards: 5-6KINTERFACE
    5-6K Interface Evaluation Module
    Lifecycle Status: Active (Recommended for new designs)

Application Notes

  • Interfacing Low Power Serial (SPI) ADCs to the MSP430F449
    PDF, 407 Kb, File published: Feb 4, 2005
    This application report discusses the serial peripheral interface (SPI) implementation of a data acquisition system featuring the following devices: TLV2541, TLC2551, TLC3541, and TLC4541. These analog-to-digital converters (ADC) offer options for users ranging from extremely low power and wide voltage supply range to fast conversion throughput. All devices share a small (MSOP) footprint and are p
  • Determining Minimum Acquisition Times for SAR ADCs, part 2
    PDF, 215 Kb, File published: Mar 17, 2011
    The input structure circuit of a successive-approximation register analog-to-digital converter (SAR ADC) incombination with the driving circuit forms a transfer function that can be used to determine minimum acquisition times for different types of applied input signals. This application report, which builds on Determining Minimum Acquisition Times for SAR ADCs When a Step Function is Applied to

Model Line

Manufacturer's Classification

  • Semiconductors > Data Converters > Analog-to-Digital Converters (ADCs) > Precision ADCs (<=10MSPS)
EMS supplier