Datasheet Texas Instruments JM38510/34002B2A

ManufacturerTexas Instruments
SeriesSN54F11
Part NumberJM38510/34002B2A
Datasheet Texas Instruments JM38510/34002B2A

Triple 3-Input Positive-AND Gates 20-LCCC -55 to 125

Datasheets

Triple 3-Input Positive-AND Gates datasheet
PDF, 877 Kb, Revision: A, File published: Oct 1, 1993
Extract from the document

Prices

Status

Lifecycle StatusActive (Recommended for new designs)
Manufacture's Sample AvailabilityNo

Packaging

Pin2020
Package TypeFKFK
Industry STD TermLCCCLCCC
JEDEC CodeS-CQCC-NS-CQCC-N
Package QTY11
CarrierTUBETUBE
Device MarkingJM38510/34002B2A
Width (mm)8.898.89
Length (mm)8.898.89
Thickness (mm)1.831.83
Pitch (mm)1.271.27
Max Height (mm)2.032.03
Mechanical DataDownloadDownload

Parametrics

Bits3
F @ Nom Voltage(Max)70 Mhz
ICC @ Nom Voltage(Max)0.0062 mA
Input TypeTTL
Operating Temperature Range-55 to 125 C
Output Drive (IOL/IOH)(Max)-40/40 mA
Output TypeTTL
Package GroupLCCC
Package Size: mm2:W x L20LCCC: 79 mm2: 8.89 x 8.89(LCCC) PKG
RatingMilitary
Schmitt TriggerNo
Technology FamilyF
VCC(Max)5.5 V
VCC(Min)4.5 V
tpd @ Nom Voltage(Max)7.5 ns

Eco Plan

RoHSSee ti.com

Application Notes

  • Bus-Interface Devices With Output-Damping Resistors Or Reduced-Drive Outputs (Rev. A)
    PDF, 105 Kb, Revision: A, File published: Aug 1, 1997
    The spectrum of bus-interface devices with damping resistors or balanced/light output drive currently offered by various logic vendors is confusing at best. Inconsistencies in naming conventions and methods used for implementation make it difficult to identify the best solution for a given application. This report attempts to clarify the issue by looking at several vendors? approaches and discussi

Model Line

Manufacturer's Classification

  • Semiconductors > Space & High Reliability > Logic Products > Gate Products
EMS supplier