Datasheet RH1021-5 (Analog Devices) - 3

ManufacturerAnalog Devices
DescriptionPrecision 5V Reference
Pages / Page6 / 3 — TABLE 1A: ELECTRICAL CHARACTERISTICS (Postirradiation) (Note 6). …
RevisionF
File Format / SizePDF / 604 Kb
Document LanguageEnglish

TABLE 1A: ELECTRICAL CHARACTERISTICS (Postirradiation) (Note 6). 10Krad(Si). 20Krad(Si). 50Krad(Si). 100Krad(Si). 200Krad(Si)

TABLE 1A: ELECTRICAL CHARACTERISTICS (Postirradiation) (Note 6) 10Krad(Si) 20Krad(Si) 50Krad(Si) 100Krad(Si) 200Krad(Si)

Model Line for this Datasheet

Text Version of Document

RH1021-5
TABLE 1A: ELECTRICAL CHARACTERISTICS (Postirradiation) (Note 6) 10Krad(Si) 20Krad(Si) 50Krad(Si) 100Krad(Si) 200Krad(Si) SYMBOL PARAMETER CONDITIONS NOTES MIN MAX MIN MAX MIN MAX MIN MAX MIN MAX UNITS
VOUT Output Voltage RH1021CM-5 1 4.9945 5.0055 4.993 5.007 4.991 5.009 4.9875 5.0125 4.984 5.016 V RH1021BM-5, DM-5 1 4.95 5.05 4.945 5.055 4.942 5.058 4.94 5.06 4.935 5.065 V TCVOUT Output Voltage RH1021BM-5 2 5 5 5 7 10 ppm/°C Temperature Coefficient RH1021CM-5, DM-5 2 20 20 20 22 25 ppm/°C ∆VOUT Line Regulation 7.2V ≤ VIN ≤ 10V 3 12 12 13.5 15 18 ppm/V ∆VIN 10V ≤ VIN ≤ 40V 3 6 6 6 7 9 ppm/V ∆VOUT Load Regulation 0 ≤ IOUT ≤ 10mA 3, 7 20 20 20 20 20 ppm/mA ∆IOUT (Sourcing Current) Load Regulation 0 ≤ IOUT ≤ 10mA 3 100 100 100 100 150 ppm/mA (Sinking Current) IS Supply Current 1.2 1.2 1.2 1.2 1.2 mA
Note 1:
Output voltage is measured immediately after turn-on. Changes as opposed to RMS. Correction factors are used to convert from average due to chip warm-up are typically less than 0.005%. to RMS and to correct for the nonideal bandpass of the filters. Peak-to-
Note 2:
Temperature coefficient is measured by dividing the change in peak noise is measured with a single highpass filter at 0.1Hz and a 2-pole output voltage over the temperature range by the change in temperature. lowpass filter at 10Hz. The unit is enclosed in a still-air environment to Separate tests are done for hot and cold; T eliminate thermocouple effects on the leads. Test time is 10 seconds. MIN to 25°C and 25°C to TMAX. Incremental slope is also measured at 25°C.
Note 5:
Consult factory for units with long term stability data.
Note 3:
Line and load regulation are measured on a pulse basis. Output
Note 6:
VIN = 10V, IOUT = 0, TA = 25°C, unless otherwise noted. changes due to die temperature change must be taken into account
Note 7:
IOUT(MAX) (Sourcing) is 5mA for exposures greater than separately. Package thermal resistance is 150°C/W for the TO-5 (H) 100Krad (Si). package and 170°C/W for the 10-lead flatpack (W) package.
Note 8:
VIN = 10V, IOUT = 0, unless otherwise noted.
Note 4:
RMS noise is measured with a 2-pole highpass filter at 10Hz and
Note 9:
Absolute Maximum Ratings are those values beyond which the life a 2-pole lowpass filter at 1kHz. The resulting output is full wave rectified of a device may be impaired. and then integrated for a fixed period, making the final reading an average Rev F 3 Document Outline Description Absolute Maximum Ratings Burn-In Circuits Pin Configuration Order Information Table 1: Electrical Characteristics Table 1A: Electrical Characteristics Table 2: Electrical Test Requirements Total Dose Bias Circuit Revision History Typical Performance Characteristics
EMS supplier