The "I×V = W" converter comprises voltage-to-frequency conversion (U1ab & A1a) with frequency (F) of 2000 × VLOAD, followed by frequency-to-voltage, VW, conversion where VLOAD < 33 V and ILOAD < 1.5 A

AuthorsStephen Woodward
Main DocumentArticle «Amps x Volts = Watts»
DescriptionFigure 1
File Format / SizePDF / 24 Kb
Document LanguageEnglish

The I×V = W converter comprises voltage-to-frequency conversion (U1ab & A1a) with frequency (F) of 2000 × V sub LOAD /sub , followed by frequency-to-voltage, V sub W /sub , conversion where V sub LOAD /sub    33 V and I sub LOAD /sub    1.5 A