.. Figure 2 shows. Figure 2. An LED driver provides current for the LED under test. When S 2 is in the upper position, the meter measures voltage across R 1 , a 1-kΩ resistor; the meter displays a negative-voltage-drop value. R 1 ...
.. thermal problems by simply probing a suspicious component with the sensing diode. The circuit, including the indicating meter, can fit into a small housing, such as an empty 20 g glue-stick tube. An ordinary 1N4148 silicon signal diode ...
.. more precision adjustment is possible. Perhaps 5 V for LM393 is not required; ground would do in this case. b) The wind meter works on the same principle as a hot-wire anemometer. The simple wind meter (Figure 2b) operates on the same ...
.. 51.96 3.17 Figure 2. R S of the inductor. To test these ideas, I picked the components listed in Table 2 and used an LCR meter to measure their actual characteristics (Figure 2). I plugged the values into the spreadsheet to predict T H , ...
.. to feed a 5 V regulator IC, such as a 7805 voltmeter and add an on/off switch if desired. Place the batteries near the meter. Otherwise, the batteries' steel cases will disturb the magnetic field under observation. Use 10-nF SMD ...
.. Idea illustrates this by using all six inverters in a 4069 package to make a closed loop, duty-cycle-based capacitance meter with a full scale deflection below one picofarad. The inverters exhibit stable output with a direct feedback ...
.. previous Design Idea describes an interesting and useful method for using a moving-coil analog meter to measure currents in the less-than-1A range ( Reference 1 ). The design offers considerable flexibility in ...
.. the resulting voltage, averaged by C2 and C3, is measured by an external voltmeter. Figure 2. Complete schematic of C and L meter. Transients with an exponential decay that extend over a particular portion of the square wave period will ...