Circuits & Schematics: frequency meter - 3

Search for: "frequency meter"
Search results: 850 Output: 21-30   Including: frequency (779); meter (106).
  1. .. supply, mains wiring or other electrical device. There will be a deflection on the meter and sound in the headphones if the frequency is below 15KHz. Parts List IC1 TL084 D1 1N4148 L1 1mH radial inductor part 187LY-102J R1 470k R2, R5, ...
    .. of the probe cable, and the impedance of the inductor itself. The cable capacitance was measured by a capacitance meter and came out at 1.9pF, so 2pF was added in parallel with L2 which is the probe inductor. The simulation ...
    Sep 7, 2010
  1. .. With a large color television or color monitor flyback, 30,000 V or more will be made possible with 24 VDC. The operating frequency is in KHz to 10 KHz range depending seconds of VDC, the load and the specific flyback. You can ...
    .. to a high-voltage multiplier or HV rectifier diodes rectifiers decline is far greater than the battery voltage used in your meter. However, a connection with a liquidation infinite resistance to all other terminals may be the HV return. The ...
    Dec 5, 2010
  1. Rachel Hageman Steve Hageman
    .. circuit in Figure 1 was to locate coins, but it applies wherever you need to locate metal objects. The circuit uses a beat-frequency technique: Whenever a metal object comes close to the search coil, the metal causes the coil’s ...
    .. because they will lock with each other, thereby reducing the search oscillator’s sensitivity. You can add a meter output for visual or automatic control by adding a highpass filter to the LM389’s output. This highpass ...
    Feb 5, 2025
  2. .. displays, and it may be useful in designing a lowcomponent- count, low-power, and lowcost LED-display module for a 24-bit frequency meter, for example. You can use the circuit in Figure 1 to replace classical designs for digital ...
    Jun 10, 2011
  3. .. intended for RF wireless applications in the sub-1 GHz band. It is designed to operate both in the license-free ISM and SRD frequency bands at 169, 315, 433, 868 and 915 MHz. This application note outlines the expected performance when ...
    .. when using the SPIRIT1 with a range extender under EN 300 220-1 (v2.3.1, 2012-02) in the 169.400 - 169.475 MHz band, meter reading, tracking and tracing applications. The maximum allowed output power in this sub-band is +27 dBm (500 ...
    Nov 22, 2013
  4. Lyle Williams
    .. at a supersonic rate for instance, 25 kHz. The rate that the oscillation is switched off and on is called the quench frequency. This frequency should be above the limit of human hearing, but otherwise as low as possible. High ...
    .. from the form. The coil is tapped one half turn from the 9 volt supply side to make a connection for the antenna. A one meter long wire antenna is sufficient. The 0.04 to 6 pF capacitor is used to tune in stations. The tuner needs an ...
    Oct 18, 2016
  5. .. comparator’s output goes high, an audio-relaxation oscillator built around the other half of U1 is also enabled. The frequency of this oscillator is adjusted by R8 and C3 to be in the audio range (1300 Hz for the values ...
    .. available; one good choice is Audio Test set [ 2 ] from Darkwood Designs. This free software also incorporates a level meter which measures the input-voltage level applied to the mic/line input of the computer’s sound card (Fig. ...
    Nov 25, 2016
  6. .. This current is necessary to track the RF-modulation envelope and depends on the size of the input capacitor, modulation frequency, and maximum signal amplitude. The reverse current, which is I BASE times the reverse beta, must be ...
    .. levels and that the 2N3904 has a bit less offset, as you would expect from Figure 2. The output can drive a signal level meter or following electronics as part of an automatic-level-control or automatic-gain-control loop. Figure 4. Using ...
    Dec 14, 2016
  7. .. compact form factor, simplifying layout design and reducing solution size. Only input and output capacitors, frequency and voltage setting resistors are necessary to complete the design. A typical application circuit and ...
    .. Ultralow Noise: CISPR 22 Class B Figure 6. EMI Performance vs CISPR 22 Class B for 12 V IN to 3.3 V OUT at 1.2 A (3 meter, Peak, Vertical Antenna, No EMI Filter). Switching regulators naturally produce radiated EMI, as their ...
    Jan 30, 2019
  8. .. signals over a wide dynamic range, but are not rms-responding. An alternative solution (Figure 1) uses the AD8361, a high-frequency true-power detector. Unlike the logarithmic amplifier, the AD8361 is an rms-to-dc converter and, ...
    .. output voltage that is proportional to the input power level in watts. You can easily adjust gain and offset for this power meter with an op-amp circuit, thus providing an output scaled in volts per watt. A complex RF waveform feeds the ...
    Sep 13, 2020

Sort by: relevance / date

Search "frequency meter" on other search engines: Only-DataSheet.com Google