Circuits & Schematics Measurement: oscilloscope - 3

Subsection: "Measurement"
  Including:
  Oscilloscopes
Search results: 44 Output: 21-30
  1. Circuits Measurement Maxim MAX427 MAX4372
    .. offset adjustment : Connect a 1-kHz, 5 V p-p sinusoidal signal to the Y input, and connect the X input to ground. Using an oscilloscope to monitor the output, adjust R X for an ac null (zero amplitude) in the sinusoidal signal. ...
    31-05-2017
  1. Circuits Measurement Linear Technology LT1460 LTC1150 LTC6943
    .. C 1 resets IC 2A 's output to its high state, and the ramp-and-reset action continues. Figure 2. On a 700-MHz real-time oscilloscope, the oscillator-core waveforms at a 40-MHz operating frequency show the ramp-and-reset waveform ...
    19-01-2017
  1. .. are as short as possible and as close as possible to the copper-clad board. The layout is such that you don't need the oscilloscope probe's ground lead; the ground on the probe contacts a ground post on the pc board. The ...
    01-12-2016
  2. .. test current to the DUT. U2 then raises V CE(DUT) to 2 V and regulates it. Figure 3. The falling edge of Q A triggers an oscilloscope, which uses V RB1 (trace A) and V RC1 (trace B) to calculate h FE (trace D). The high-to-low ...
    31-05-2016
  3. .. the magic of waves. Despite jaw-dropping computer graphic technologies, creating Lissajous patterns and other images on a oscilloscope is still exciting. Many online pages explain them in detail and show several popular patterns. ...
    10-03-2016
  4. .. an alternative: an inexpensive and well-protected unity-gain probe that presents the same input impedance as a basic bench oscilloscope and can drive the spectrum analyzer's 50 Ω input impedance. The probe has a gain of 0 ...
    14-02-2016
  5. .. high bandwidth means for measuring the pulsing current. A straight 50 Ω coax can be connected directly to an oscilloscope input for monitoring current with a scale of 1 mV/A. The voltage measurement should also be made ...
    04-11-2015
  6. Josef Valasek EDN If you develop an application on a small microcontroller, your diagnostic tools for debugging of the program code might be very limited. This Design Idea introduces a simple debugging routine for plotting the binary value of one ...
    20-05-2015
  7. .. Phase. Jitter. Jitter - Jitter is the short-term frequency instability and is normally seen in the time domain on an oscilloscope. Phase Noise - Phase Noise is a ratio of signal power to noise power normalized to a 1 Hz ...
    30-11-2013
  8. .. 100 ppm which is not suitable for any accurate measurements. If we have another device to measure the exact frequency (eg oscilloscope with hardware measurement), we can calibrate our circuit by adding a little trimming (cap pot) ...
    17-05-2013

Sort by: relevance / date

Search "oscilloscope" on other search engines: Only-DataSheet.com Google
EMS supplier